Literature DB >> 22071383

Implantable loop recorders are cost-effective when used to investigate transient loss of consciousness which is either suspected to be arrhythmic or remains unexplained.

Sarah Davis1, Maggie Westby, David Pitcher, Sanjiv Petkar.   

Abstract

AIMS: To assess the cost-effectiveness of implantable loop recorders (ILRs) in people with transient loss of consciousness (TLoC), which, after initial assessment and specialist cardiovascular assessment, is either suspected to be arrhythmic in origin or remains unexplained. This analysis was conducted to inform clinical guideline recommendations made by the National Institute for Health and Clinical Excellence (NICE) on the management of TLoC. METHODS AND
RESULTS: Decision analytic modelling was used to estimate the costs and benefits of using ILRs compared with a strategy of no further diagnostic testing. Diagnostic outcomes were estimated from a systematic review and used to populate a decision tree model. To capture the main consequences of diagnosis, the costs and benefits of treatment for several clinically significant arrhythmias were estimated within the model. We used a cost-utility approach, in which benefits are measured using quality adjusted life years (QALYs), and took a UK National Health Service (NHS) and personal social services perspective. The cost per QALY was £17,400 in patients with unexplained syncope and £16,400 in patients with suspected arrhythmic syncope. Sensitivity analysis found that the cost-effectiveness estimates are fairly robust despite the areas of uncertainty identified in the evidence and assumptions used to inform the model.
CONCLUSIONS: Implantable loop recorder monitoring is likely to be a cost-effective strategy in people presenting to the UK NHS who are experiencing infrequent episodes of TLoC which either remain unexplained or are suspected to be arrhythmic after initial assessment and specialist cardiovascular assessment. Implantable loop recorder monitoring has been recommended by NICE for these populations.

Entities:  

Mesh:

Year:  2011        PMID: 22071383     DOI: 10.1093/europace/eur343

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  9 in total

Review 1.  Recommendations on the use of innovative medical technologies in cardiology and cardiac surgery and solutions leading to increased availability for Polish patients.

Authors:  Dariusz Dudek; Waldemar Banasiak; Wojciech Braksator; Jacek Dubiel; Tomasz Grodzicki; Piotr Hoffman; Mariusz Kuśmierczyk; Grzegorz Opolski; Piotr Ponikowski; Jacek Różański; Jerzy Sadowski; Wojciech Wojakowski; Marcin Grabowski; Katarzyna Bondaryk; Jacek Walczak; Izabela Pieniążek; Maciej Grys; Anna Lesiak-Bednarek; Piotr Przygodzki
Journal:  Cardiol J       Date:  2019-02-14       Impact factor: 2.737

Review 2.  Key challenges in the current management of syncope.

Authors:  Richard Sutton; Michele Brignole; David G Benditt
Journal:  Nat Rev Cardiol       Date:  2012-07-17       Impact factor: 32.419

3.  Efficacy And Safety Of Implantable Loop Recorder: Experience Of A Center.

Authors:  Inês Silveira; Maria João Sousa; Nuno Antunes; Vânia Silva; Carla Roque; António Pinheiro-Vieira; Vítor Lagarto; António Hipólito-Reis; André Luz; Severo Torres
Journal:  J Atr Fibrillation       Date:  2016-08-31

4.  Implantable loop recorders in patients with unexplained syncope: Clinical predictors of pacemaker implantation.

Authors:  Martin Huemer; Ann-Kristin Becker; Alexander Wutzler; Philipp Attanasio; Abdul S Parwani; Philipp Lacour; Leif-Hendrik Boldt; Burkert Pieske; Wilhelm Haverkamp; Florian Blaschke
Journal:  Cardiol J       Date:  2018-02-05       Impact factor: 2.737

5.  External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study.

Authors:  E T Locati; A Moya; M Oliveira; H Tanner; R Willems; M Lunati; M Brignole
Journal:  Europace       Date:  2015-10-29       Impact factor: 5.214

6.  Cost-effectiveness of an insertable cardiac monitor in a high-risk population in the UK.

Authors:  Claudia I Rinciog; Laura M Sawyer; Alexander Diamantopoulos; Mitchell S V Elkind; Matthew Reynolds; Stylianos I Tsintzos; Paul D Ziegler; Maria E Quiroz; Claudia Wolff; Klaus K Witte
Journal:  Open Heart       Date:  2019-06-20

7.  Costs of unstructured investigation of unexplained syncope: insights from a micro-costing analysis of the observational PICTURE registry.

Authors:  Nils Edvardsson; Claudia Wolff; Stelios Tsintzos; Guido Rieger; Nicholas J Linker
Journal:  Europace       Date:  2015-03-10       Impact factor: 5.214

8.  Financial impact of adopting implantable loop recorder diagnostic for unexplained syncope compared with conventional diagnostic pathway in Portugal.

Authors:  Rui Providência; Rui Candeias; Carlos Morais; Hipólito Reis; Luís Elvas; Vitor Sanfins; Sara Farinha; Simon Eggington; Stelios Tsintzos
Journal:  BMC Cardiovasc Disord       Date:  2014-05-06       Impact factor: 2.298

9.  Economic value of insertable cardiac monitors in unexplained syncope in the United States.

Authors:  Brad S Sutton; Sarah L Bermingham; Alexander Diamantopoulos; Sarah C Rosemas; Stelios I Tsintzos; Ying Xia; Matthew R Reynolds
Journal:  Open Heart       Date:  2021-02
  9 in total