Optimal surgical positioning of cable-screw pairs in repairing periprosthetic femur fractures near the tip of a total hip implant still remains unclear. No studies in the literature to date have developed a fully three-dimensional finite element (FE) model that has been validated experimentally to assess these injury patterns. The aim of the present study was to evaluate the biomechanical performance of three different implant-bone constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. Experimentally, three bone-plate repair configurations were applied to the periprosthetic synthetic femur fractured with a 5 mm gap near the tip of a total hip implant. Constructs A, B, and C, respectively, had successively larger distances between the most proximal and the most distal cable-screw pairs used to affix the plate. Specimens were oriented in 15 degrees adduction, subjected to 1000 N of axial force to simulate the single-legged stance phase of walking, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic three-dimensional FE model was developed to mimic the experimental setup. Results showed excellent agreement between experimental versus FE analysis strains, yielding a Pearson linearity coefficient, R2, of 0.90 and a slope for the line of best data fit of 0.96. FE axial stiffnesses were 601 N/mm (Construct A), 849 N/mm (Construct B), and 1359 N/mm (Construct C). FE surface stress maps for cortical bone showed maximum von Mises values of 74 MPa (Construct A), 102 MPa (Construct B), and 57 MPa (Construct C). FE stress maps for the metallic components showed minimum von Mises values for Construct C, namely screw (716MPa), cable (445MPa), plate (548MPa), and hip implant (154MPa). In the case of good bone stock, as modelled by the present synthetic femur model, optimal fixation can be achieved with Construct C.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22070023     DOI: 10.1177/0954411911410642

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  6 in total

1.  Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.

Authors:  Gregory S Lewis; Cyrus T Caroom; Hwabok Wee; Darin Jurgensmeier; Shane D Rothermel; Michelle A Bramer; John Spence Reid
Journal:  J Orthop Trauma       Date:  2015-10       Impact factor: 2.512

2.  Biomechanical Analysis Using FEA and Experiments of Metal Plate and Bone Strut Repair of a Femur Midshaft Segmental Defect.

Authors:  Jason Coquim; Joseph Clemenzi; Mohsen Salahi; Abdurahman Sherif; Pouria Tavakkoli Avval; Suraj Shah; Emil H Schemitsch; Z Shaghayegh Bagheri; Habiba Bougherara; Radovan Zdero
Journal:  Biomed Res Int       Date:  2018-10-18       Impact factor: 3.411

3.  Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis.

Authors:  Shi Zhan; Dajun Jiang; Jian Xu; Ming Ling; Kai Yang; Yuehua Li; Weitao Jia; Hai Hu; Changqing Zhang
Journal:  BMC Musculoskelet Disord       Date:  2020-12-12       Impact factor: 2.362

4.  Spatial Bridge Locking Fixator versus Traditional Locking Plates in Treating AO/OTA 32-A3.2 Fracture: Finite Element Analysis and Biomechanical Evaluation.

Authors:  Jianwei Hu; Ye Peng; Jiantao Li; Ming Li; Ying Xiong; Jiayu Xiao; Licheng Zhang; Peifu Tang
Journal:  Orthop Surg       Date:  2022-06-22       Impact factor: 2.279

Review 5.  Experimental testing of fracture fixation plates: A review.

Authors:  Shiling Zhang; Dharmesh Patel; Mark Brady; Sherri Gambill; Kanthan Theivendran; Subodh Deshmukh; John Swadener; Sarah Junaid; Laura Jane Leslie
Journal:  Proc Inst Mech Eng H       Date:  2022-08-03       Impact factor: 1.763

6.  Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures.

Authors:  Dajun Jiang; Shi Zhan; Lei Wang; Lewis L Shi; Ming Ling; Hai Hu; Weitao Jia
Journal:  J Orthop Res       Date:  2020-10-23       Impact factor: 3.494

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.