Literature DB >> 22068062

Bedside ultrasound diagnosis of nonangulated distal forearm fractures in the pediatric emergency department.

Frances M Chaar-Alvarez1, Fred Warkentine, Keith Cross, Sandra Herr, Ronald I Paul.   

Abstract

OBJECTIVES: Ultrasound (US) may be a useful tool for rapidly diagnosing fractures. Our objective was to determine the accuracy of US as compared with radiographs in the detection of nonangulated distal forearm fractures.
METHODS: Distal forearm US was performed and interpreted at the bedside by a pediatric emergency medicine physician before radiography in a prospective sample of children with possible nonangulated distal forearm fractures. A second pediatric emergency medicine physician with extensive US experience gave a final interpretation of the images. This second reviewer was blinded to both clinical and radiographic findings. The primary outcome was accuracy in the detection of fracture via the blinded reviewer's US interpretation when compared with the radiologist's clinical radiography results. Patient-reported FACES pain scores (range, 0-5) associated with both US and radiography were compared.
RESULTS: Of 101 enrolled patients, 46 had a fracture detected by the radiologist. When compared with radiographs, the blinded US interpretation had an overall accuracy of 94% (95% confidence interval [CI], 88%-99%). Sensitivity and specificity were 96% (95% CI, 85%-99%) and 93% (95% CI, 82%-98%), respectively. Positive predictive value was 92%, and negative predictive value was 96%. Mean FACES pain scores were higher following radiography than US (1.7 vs 1.2, respectively; P = 0.004).
CONCLUSIONS: For the diagnosis of nonangulated distal forearm fractures in children, bedside US holds promise as a diagnostic modality, particularly with appropriate training. Ultrasound is at least no more painful that traditional radiographs. Pediatric emergency medicine physicians should consider becoming proficient in this application.

Entities:  

Mesh:

Year:  2011        PMID: 22068062     DOI: 10.1097/PEC.0b013e318235e228

Source DB:  PubMed          Journal:  Pediatr Emerg Care        ISSN: 0749-5161            Impact factor:   1.454


  16 in total

1.  Accuracy of the sonographic fat pad sign for primary screening of pediatric elbow fractures: a preliminary study.

Authors:  Kolja Eckert; Ole Ackermann; Niklas Janssen; Bernd Schweiger; Elke Radeloff; Peter Liedgens
Journal:  J Med Ultrason (2001)       Date:  2014-03-06       Impact factor: 1.314

Review 2.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

3.  The Investigation of Suspected Fracture-a Comparison of Ultrasound With Conventional Imaging.

Authors:  Gordian Lukas Schmid; Stefan Lippmann; Susanne Unverzagt; Christiane Hofmann; Tobias Deutsch; Thomas Frese
Journal:  Dtsch Arztebl Int       Date:  2017-11-10       Impact factor: 5.594

Review 4.  [Fracture sonography of the extremities].

Authors:  Ole Ackermann
Journal:  Unfallchirurg       Date:  2021-12-18       Impact factor: 1.000

5.  [Intraoperative imaging of children and adolescents, for selected fractures and in follow-up after conservative and operative treatment : Part 2 of the results of a nationwide online survey of the Pediatric Traumatology Section of the German Trauma Society].

Authors:  Klaus Dresing; Francisco Fernandez; Peter Schmittenbecher; Kaya Dresing; Peter Strohm; Christopher Spering; Ralf Kraus
Journal:  Unfallchirurg       Date:  2021-12-16       Impact factor: 1.000

6.  Ultrasound diagnosis of supracondylar fractures in children.

Authors:  K Eckert; N Janssen; O Ackermann; B Schweiger; E Radeloff; P Liedgens
Journal:  Eur J Trauma Emerg Surg       Date:  2013-06-11       Impact factor: 3.693

7.  [Necessity for radiological examinations in children : Children in two levels].

Authors:  H Vossschulte; C Thaumüller; W Barthlen
Journal:  Unfallchirurg       Date:  2020-01       Impact factor: 1.000

8.  Ultrasound-Assisted Distal Radius Fracture Reduction.

Authors:  Steve Socransky; Andrew Skinner; Mark Bromley; Andrew Smith; Alexandre Anawati; Jeff Middaugh; Peter Ross; Paul Atkinson
Journal:  Cureus       Date:  2016-07-07

9.  Emergency physicians performed Point-of-Care-Ultrasonography for detecting distal forearm fracture.

Authors:  Semra Sivrikaya; Ersin Aksay; Basak Bayram; Nese Colak Oray; Ahmet Karakasli; Emel Altintas
Journal:  Turk J Emerg Med       Date:  2016-05-19

Review 10.  Ultrasound for Distal Forearm Fracture: A Systematic Review and Diagnostic Meta-Analysis.

Authors:  Djoke Douma-den Hamer; Marco H Blanker; Mireille A Edens; Lonneke N Buijteweg; Martijn F Boomsma; Sven H van Helden; Gert-Jan Mauritz
Journal:  PLoS One       Date:  2016-05-19       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.