Literature DB >> 22067226

Local morphology fitting active contour for automatic vascular segmentation.

Kaiqiong Sun1, Zhen Chen, Shaofeng Jiang.   

Abstract

In this paper, we propose an active contour model using local morphology fitting for automatic vascular segmentation on 2-D angiogram. The vessel and background are fitted to fuzzy morphology maximum and minimum opening, separately, using linear structuring element with adaptive scale and orientation. The minimization of the energy associated with the active contour model is implemented within a level set framework. As in the current local model, fitting the image to local region information makes the model robust against the inhomogeneous background. Moreover, selective local estimations for fitting that are precomputed instead of updated in each contour evolution makes the evolution of level set robust again initial location compared to the current local model. The results on synthetic image and real angiogram compared with other methods are presented. It is shown that the proposed method can achieve automatic and accurate segmentation of vascular angiogram.
© 2011 IEEE

Mesh:

Year:  2011        PMID: 22067226     DOI: 10.1109/TBME.2011.2174362

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

Review 1.  Automated analysis of diabetic retinopathy images: principles, recent developments, and emerging trends.

Authors:  Baoxin Li; Helen K Li
Journal:  Curr Diab Rep       Date:  2013-08       Impact factor: 4.810

2.  Retinal vessel segmentation: an efficient graph cut approach with retinex and local phase.

Authors:  Yitian Zhao; Yonghuai Liu; Xiangqian Wu; Simon P Harding; Yalin Zheng
Journal:  PLoS One       Date:  2015-04-01       Impact factor: 3.240

3.  Bayesian method with spatial constraint for retinal vessel segmentation.

Authors:  Zhiyong Xiao; Mouloud Adel; Salah Bourennane
Journal:  Comput Math Methods Med       Date:  2013-07-14       Impact factor: 2.238

4.  Inter/intra-frame constrained vascular segmentation in X-ray angiographic image sequence.

Authors:  Shuang Song; Chenbing Du; Ying Chen; Danni Ai; Hong Song; Yong Huang; Yongtian Wang; Jian Yang
Journal:  BMC Med Inform Decis Mak       Date:  2019-12-19       Impact factor: 2.796

5.  A vessel active contour model for vascular segmentation.

Authors:  Yun Tian; Qingli Chen; Wei Wang; Yu Peng; Qingjun Wang; Fuqing Duan; Zhongke Wu; Mingquan Zhou
Journal:  Biomed Res Int       Date:  2014-07-01       Impact factor: 3.411

6.  A robust statistics driven volume-scalable active contour for segmenting anatomical structures in volumetric medical images with complex conditions.

Authors:  Kuanquan Wang; Chao Ma
Journal:  Biomed Eng Online       Date:  2016-04-14       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.