Literature DB >> 22066738

Comparison of annular diffusion denuder and high volume air samplers for measuring per- and polyfluoroalkyl substances in the atmosphere.

Lutz Ahrens1, Mahiba Shoeib, Tom Harner, Douglas A Lane, Rui Guo, Eric J Reiner.   

Abstract

Overestimation of the particle phase concentration collected on glass-fiber filters (GFFs) has been reported for perfluoroalkyl carboxylic acids (PFCAs) using conventional high volume air samplers. In this study, per- and polyfluoroalkyl substances (PFASs) were determined in the gas and particulate phases using colocated annular diffusion denuder and high volume air samplers at a semiurban site in Toronto, Canada, in winter 2010. Samples were analyzed for 7 PFAS classes (i.e., PFCAs, perfluoro-alkane sulfonic acids (PFSAs), fluorotelomer alcohols (FTOHs), fluorotelomer methacrylates (FTMACs), fluorotelomer acrylates (FTACs), perfluorooctane sulfonamides (FOSAs), and perfluorooctane sulfonamidoethanols (FOSEs)). The gas diffusion coefficients for individual PFASs were calculated and the denuder performance was evaluated. Modeled subcooled liquid vapor pressures (p(L)) correlated well with the vapor phase breakthrough for the denuder and high volume air systems. Total air concentrations for PFASs measured using annular diffusion denuders and high volume samplers were in agreement within a factor of 4; however, much greater differences were observed for measurements of gas-particle partitioning. Vapor phase PFSAs and PFCAs can adsorb to the GFF using high volume air samplers, resulting in much higher particle-associated fractions for these chemicals compared to the annular diffusion denuder sampler. This effect was not observed for the FTOHs, FTMACs, FTACs, FOSAs, and FOSEs. Thus, for investigations of gas-particle partitioning of PFSAs and PFCAs, the diffusion denuder sampler is the preferred method. The results of this study improve our understanding of the gas-particle partitioning of PFASs, which is important for modeling their long-range transport in air.

Entities:  

Year:  2011        PMID: 22066738     DOI: 10.1021/ac202414w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Field-testing polyethylene passive samplers for the detection of neutral polyfluorinated alkyl substances in air and water.

Authors:  Erik Dixon-Anderson; Rainer Lohmann
Journal:  Environ Toxicol Chem       Date:  2018-11-05       Impact factor: 3.742

2.  Per- and Polyfluoroalkyl Substances (PFASs) in Airborne Particulate Matter (PM2.0) Emitted During Floor Waxing: A Pilot Study.

Authors:  Jiaqi Zhou; Karsten Baumann; Naomi Chang; Glenn Morrison; Wanda Bodnar; Zhenfa Zhang; Joanna M Atkin; Jason D Surratt; Barbara J Turpin
Journal:  Atmos Environ (1994)       Date:  2021-11-10       Impact factor: 4.798

3.  Low Temperature Thermal Treatment of Gas-Phase Fluorotelomer Alcohols by Calcium Oxide.

Authors:  Theran P Riedel; M Ariel Geer Wallace; Erin P Shields; Jeffrey V Ryan; Chun Wai Lee; William P Linak
Journal:  Chemosphere       Date:  2021-02-06       Impact factor: 8.943

4.  Survey of per- and polyfluoroalkyl substances (PFAS) in surface water collected in Pensacola, FL.

Authors:  Bianca Ferreira da Silva; Juan J Aristizabal-Henao; Joe Aufmuth; Jill Awkerman; John A Bowden
Journal:  Heliyon       Date:  2022-08-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.