| Literature DB >> 22063995 |
G Purcaro1, S Moret, L S Conte.
Abstract
A rapid extraction method involving microwave assisted extraction (MAE), followed by sample clean-up on a silica cartridge, reversed-phase high performance liquid chromatography (RP-HPLC) and spectrofluorimetric detection, was optimised for polycyclic aromatic hydrocarbon (PAH) determination in smoked meat. Compared to solvent extraction assisted by sonication, MAE, carried out with n-hexane on 2g of lyophilised sample at 115°C for 15min, allowed to obtain better extraction efficiencies. Limits of quantification (LOQ, s/n=10) lower than 0.2μg/kg wet weight were found for all PAHs, except for Fl (0.3μg/kg), P (0.6μg/kg) and IP (0.4μg/kg). The optimised procedure, that presented good analytical performances (with recoveries ranging from 77% to 103%, and precision within 10% for most of the PAHs), was applied to determine PAH content in different smoked meat products from the Italian market.Entities:
Year: 2008 PMID: 22063995 DOI: 10.1016/j.meatsci.2008.08.002
Source DB: PubMed Journal: Meat Sci ISSN: 0309-1740 Impact factor: 5.209