Literature DB >> 22063563

A novel direct-injection photometric detector integrated with solenoid pulse-pump flow system.

Stanislawa Koronkiewicz1, Slawomir Kalinowski.   

Abstract

A novel flow photometric detector based on paired emitter-detector diodes (PEDD), coupled with solenoid pulse micro-pumps is presented. The photometric detection chamber also plays a role of the reaction chamber. Both solutions, a sample and a reagent, are injected by solenoid micro-pumps directly and simultaneously into the chamber in countercurrent. This method ensures fast and effective mixing of the injected solutions. A good accuracy and precision of the injected volumes assure the pulse micro-pumps. This method, in comparison with other flow methods, does not require the application of the reaction coil. Thanks to this, the dispersion of the sample is minimized. The presented flow network is easy to control, miniaturize and exhibits a very low consumption of reagents and the sample. Two chemical systems were chosen and presented as models of photometric reactions: the first - Fe(III) with thiocyanate, and the second - Cr(VI) with 1,5-diphenylcarbazide. To obtain the highest repeatability, the total volume of the solutions should be smaller than the volume of the reaction-detection chamber. In this case, the whole coloured product remains in the chamber. The use of the proposed direct-injection PEDD detector considerably simplifies analytical procedures. The shape of analytical signals and their potential applications have been discussed. Copyright Â
© 2011 Elsevier B.V. All rights reserved.

Entities:  

Year:  2011        PMID: 22063563     DOI: 10.1016/j.talanta.2011.08.055

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Towards optoelectronic urea biosensors.

Authors:  Marta Pokrzywnicka; Robert Koncki; Łukasz Tymecki
Journal:  Anal Bioanal Chem       Date:  2015-01-27       Impact factor: 4.142

2.  A Miniaturized Colorimeter with a Novel Design and High Precision for Photometric Detection.

Authors:  Jun-Chao Yan; Yan Chen; Yu Pang; Jan Slavik; Yun-Fei Zhao; Xiao-Ming Wu; Yi Yang; Si-Fan Yang; Tian-Ling Ren
Journal:  Sensors (Basel)       Date:  2018-03-08       Impact factor: 3.576

3.  A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples.

Authors:  Stanislawa Koronkiewicz; Mihaela Trifescu; Lech Smoczynski; Harsha Ratnaweera; Slawomir Kalinowski
Journal:  Environ Monit Assess       Date:  2018-02-12       Impact factor: 2.513

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.