| Literature DB >> 22062513 |
D Alomar1, C Gallo, M Castañeda, R Fuchslocher.
Abstract
Near infrared reflectance spectroscopy (NIRS) was evaluated as a tool to segregate different types of bovine meat and predict several chemical fractions on samples from two breeds, three muscles and six grading (Chilean system) categories. Samples previously minced, frozen and thawed, were scanned (400-2500 nm) and then analyzed for dry matter, crude protein, ether extract, total ash and collagen content, after freeze drying. Discriminant analysis using a partial least squares regression technique and cross validation, correctly identified breed and muscle type for most samples, but carcass grades, with the exception of samples from calves, were not successfully predicted. Best calibrations for chemical composition tested by cross-validation, showed R(2) and standard errors of cross validation of 0.77 and 0.58% (dry matter), 0.82 and 0.48% (crude protein), 0.82 and 0.44% (ether extract). Calibrations for total ash showed a poor, and for collagen, a very poor prediction ability.Entities:
Year: 2003 PMID: 22062513 DOI: 10.1016/s0309-1740(02)00101-8
Source DB: PubMed Journal: Meat Sci ISSN: 0309-1740 Impact factor: 5.209