Literature DB >> 22061385

Quantification of muscle, subcutaneous fat and intermuscular fat in pig carcasses and cuts by magnetic resonance imaging.

M Monziols1, G Collewet, M Bonneau, F Mariette, A Davenel, M Kouba.   

Abstract

The aim of this study was to determine the suitability of magnetic resonance imaging (MRI) to predict tissue composition of pig carcasses and cuts. Twenty-four pig carcasses were cut into the four primary cuts that were analyzed with a low field MRI imager before a total dissection. Images were then processed to identify and quantify pixels representing muscle, subcutaneous fat and intermuscular fat fractions. MRI provided a good prediction of muscle content in cuts and carcasses, with R(2) ranging from 0.970 to 0.997. The prediction was slightly less accurate for total fat (0.951⩽R(2)⩽0.986) or subcutaneous fat (0.918⩽R(2)⩽0.994). Finally, the prediction of intermuscular fat content in considering intermuscular fat classified pixels was acceptable only for the belly (R(2)=0.837).

Entities:  

Year:  2005        PMID: 22061385     DOI: 10.1016/j.meatsci.2005.06.018

Source DB:  PubMed          Journal:  Meat Sci        ISSN: 0309-1740            Impact factor:   5.209


  5 in total

1.  Nondestructive methods for quality evaluation of livestock products.

Authors:  K Narsaiah; Shyam N Jha
Journal:  J Food Sci Technol       Date:  2011-02-17       Impact factor: 2.701

Review 2.  Genetic Marker Discovery in Complex Traits: A Field Example on Fat Content and Composition in Pigs.

Authors:  Ramona Natacha Pena; Roger Ros-Freixedes; Marc Tor; Joan Estany
Journal:  Int J Mol Sci       Date:  2016-12-14       Impact factor: 5.923

Review 3.  Use of Magnetic Resonance Imaging in Food Quality Control: A Review.

Authors:  Hamed Ebrahimnejad; Hadi Ebrahimnejad; A Salajegheh; H Barghi
Journal:  J Biomed Phys Eng       Date:  2018-03-01

4.  Identification and Functional Verification Reveals that miR-195 Inhibiting THRSP to Affect Fat Deposition in Xinyang Buffalo.

Authors:  Shuzhe Wang; Cuili Pan; Xiaojie Ma; Chaoyun Yang; Lin Tang; Jieping Huang; Xuefeng Wei; Hui Li; Yun Ma
Journal:  Front Genet       Date:  2021-12-22       Impact factor: 4.599

5.  Optimization of the image acquisition procedure in low-field MRI for non-destructive analysis of loin using predictive models.

Authors:  Daniel Caballero; Trinidad Pérez-Palacios; Andrés Caro; Mar Ávila; Teresa Antequera
Journal:  PeerJ Comput Sci       Date:  2021-06-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.