Literature DB >> 22058308

Forced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics.

P D McGovern1, M Albrecht, K G Belani, C Nachtsheim, P F Partington, I Carluke, M R Reed.   

Abstract

We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were associated with the type of patient warming device that was used. Neutral-buoyancy detergent bubbles were released adjacent to the mannequin's head and at floor level to assess the movement of non-sterile air into the clean airflow over the surgical site. During simulated hip replacement, bubble counts over the surgical site were greater for forced-air than for conductive fabric warming when the anaesthesia/surgery drape was laid down (p = 0.010) and at half-height (p < 0.001). For lumbar surgery, forced-air warming generated convection currents that mobilised floor air into the surgical site area. Conductive fabric warming had no such effect. A significant increase in deep joint infection, as demonstrated by an elevated infection odds ratio (3.8, p = 0.024), was identified during a period when forced-air warming was used compared to a period when conductive fabric warming was used. Air-free warming is, therefore, recommended over forced-air warming for orthopaedic procedures.

Entities:  

Mesh:

Year:  2011        PMID: 22058308     DOI: 10.1302/0301-620X.93B11.27124

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  17 in total

1.  [Improve of surgical outcomes in spinal fusion surgery : evidence based peri- and intra-operative aspects to reduce complications and earlier recovery].

Authors:  C Fleege; A Almajali; M Rauschmann; M Rickert
Journal:  Orthopade       Date:  2014-12       Impact factor: 1.087

2.  Prevention of surgical site infections in bone and joint procedures.

Authors:  Ralf-Peter Vonberg; Petra Gastmeier
Journal:  Curr Infect Dis Rep       Date:  2012-10       Impact factor: 3.725

Review 3.  Prevention of fracture-related infection: a multidisciplinary care package.

Authors:  Willem-Jan Metsemakers; Jolien Onsea; Emilie Neutjens; Ester Steffens; Annette Schuermans; Martin McNally; Stefaan Nijs
Journal:  Int Orthop       Date:  2017-08-22       Impact factor: 3.075

4.  What is the incidence of inadvertent hypothermia in elderly hip fracture patients and is this associated with increased readmissions and mortality?

Authors:  M Williams; M Ng; M Ashworth
Journal:  J Orthop       Date:  2018-05-07

5.  Heated wire humidification circuit attenuates the decrease of core temperature during general anesthesia in patients undergoing arthroscopic hip surgery.

Authors:  Sooyong Park; Seok-Hwa Yoon; Ann Misun Youn; Seung Hyun Song; Ja Gyung Hwang
Journal:  Korean J Anesthesiol       Date:  2017-06-14

Review 6.  Forced-Air Warming Discontinued: Periprosthetic Joint Infection Rates Drop.

Authors:  Scott D Augustine
Journal:  Orthop Rev (Pavia)       Date:  2017-06-23

7.  Inadvertent hypothermia in hip and knee total joint arthroplasty.

Authors:  M Williams; Y El-Houdiri
Journal:  J Orthop       Date:  2018-01-20

8.  Reducing surgical site infection in arthroplasty of the lower limb: A multi-disciplinary approach.

Authors:  R Johnson; S S Jameson; R D Sanders; N J Sargant; S D Muller; R M D Meek; M R Reed
Journal:  Bone Joint Res       Date:  2013-03-01       Impact factor: 5.853

9.  Current Evidence for the Use of Laminar Flow in Reducing Infection Rates in Total Joint Arthroplasty.

Authors:  M James; W S Khan; M R Nannaparaju; J S Bhamra; R Morgan-Jones
Journal:  Open Orthop J       Date:  2015-09-30

10.  Comparison of forced-air and water-circulating warming for prevention of hypothermia during transcatheter aortic valve replacement.

Authors:  Benjamin Rohrer; Emily Penick; Farhad Zahedi; Hocine Tighiouart; Brian Kelly; Frederick Cobey; Stefan Ianchulev
Journal:  PLoS One       Date:  2017-06-02       Impact factor: 3.240