Literature DB >> 22058298

Simultaneous cemented and cementless total knee replacement in the same patients: a prospective comparison of long-term outcomes using an identical design of NexGen prosthesis.

J-W Park1, Y-H Kim.   

Abstract

The purpose of this prospective, randomised study was to evaluate the clinical and radiological results comparing the identical cemented or cementless NexGen total knee prostheses implanted bilaterally in the same patient. Sequential simultaneous bilateral total knee replacements were performed in 50 patients (100 knees). There were 39 women and 11 men with a mean age of 58.4 years (51 to 67) who received a cemented prosthesis in one knee and a cementless prosthesis in the other. The mean follow-up was 13.6 years (13 to 14). At final review, the mean Knee Society scores (96.2 (82 to 100) versus 97.7 (90 to 100)), the mean Western Ontario and McMaster Universities osteoarthritis index (34.5 (4 to 59) versus 35.6 (5 to 51)), the mean ranges of knee movement (124° (100° to 140°) versus 128° (110° to 140°)), mean patient satisfaction (8.1 (SD 1.9) versus 8.3 (SD 1.7)), and radiological results were similar in both groups. The rate of survival of the femoral components was 100% in both groups at 14 years. The rate of survival of the cemented tibial component was 100% and 98% in the cementless tibial component. No osteolysis was identified in either group. Our data have shown no advantage of cementless over cemented components in total knee replacement.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22058298     DOI: 10.1302/0301-620X.93B11.27507

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  23 in total

1.  Similar survival between uncemented and cemented fixation prostheses in total knee arthroplasty: a meta-analysis and systematic comparative analysis using registers.

Authors:  Hongchuan Wang; Hua Lou; Huiwei Zhang; Junwei Jiang; Kai Liu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-12-14       Impact factor: 4.342

2.  Cemented versus cementless fixation in total knee arthroplasty.

Authors:  Fabrizio Matassi; Christian Carulli; Roberto Civinini; Massimo Innocenti
Journal:  Joints       Date:  2014-01-08

3.  Similar survival between screw cementless and cemented tibial components in young patients with osteoarthritis.

Authors:  Alejandro Lizaur-Utrilla; Francisco A Miralles-Muñoz; Fernando A Lopez-Prats
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-08       Impact factor: 4.342

4.  Trabecular metal in total knee arthroplasty associated with higher knee scores: a randomized controlled trial.

Authors:  Mariano Fernandez-Fairen; Daniel Hernández-Vaquero; Antonio Murcia; Ana Torres; Rafael Llopis
Journal:  Clin Orthop Relat Res       Date:  2013-07-25       Impact factor: 4.176

5.  Comparison of long-term clinical outcomes after bilateral mobile-bearing total knee arthroplasties using PCL-retaining and PCL-substituting implants in the same patients.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Tetsuya Sakurai; Shin-Ichi Toyabe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-30       Impact factor: 4.342

6.  Cementless and cemented total knee arthroplasty in patients younger than fifty five years. Which is better?

Authors:  Young-Hoo Kim; Jang-Won Park; Hyung-Mook Lim; Eun-Soo Park
Journal:  Int Orthop       Date:  2014-01-14       Impact factor: 3.075

7.  Good long-term results following cementless TKA with a titanium plasma coating.

Authors:  Theodore Bouras; Vasileios Bitas; Peter Fennema; Panagiotis Korovessis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-03       Impact factor: 4.342

8.  Long-Term Implant Survivorship and Modes of Failure in Simultaneous Concurrent Bilateral Total Knee Arthroplasty.

Authors:  Taylor M Yong; Emily C Young; Ilda B Molloy; Brian M Fisher; Benjamin J Keeney; Wayne E Moschetti
Journal:  J Arthroplasty       Date:  2019-08-14       Impact factor: 4.757

9.  Uncemented or cemented femoral components work equally well in total knee arthroplasty.

Authors:  Anders Henricson; Radek Wojtowicz; Kjell G Nilsson; Sead Crnalic
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-25       Impact factor: 4.342

10.  Design and rationale of the ATtune Knee Outcome Study (ATKOS): multicenter prospective evaluation of a novel uncemented rotating platform knee system.

Authors:  Rachid Rassir; Inger N Sierevelt; Marjolein Schager; Peter A Nolte
Journal:  BMC Musculoskelet Disord       Date:  2021-07-15       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.