Literature DB >> 22055684

Perfusion measurement of the whole upper abdomen of patients with and without liver diseases: initial experience with 320-detector row CT.

Tomonori Kanda1, Takeshi Yoshikawa, Yoshiharu Ohno, Yasuko Fujisawa, Naoki Kanata, Masato Yamaguchi, Yasushi Seo, Yoshihiko Yano, Hisanobu Koyama, Kazuhiro Kitajima, Daisuke Takenaka, Kazuro Sugimura.   

Abstract

OBJECTIVES: To report initial experience of upper abdominal perfusion measurement with 320-detector row CT (CTP) for assessment of liver diseases and therapeutic effects.
MATERIALS AND METHODS: Thirty-eight patients who were suspected of having a liver disease underwent CTP. There were two patients with liver metastases, two with hemangiomas, and four with cirrhosis (disease group). CTP was repeated for four patients with cirrhosis or hepatocellular carcinoma (HCC) after therapy. Hepatic arterial and portal perfusion (HAP and HPP) and arterial perfusion fraction (APF), and arterial perfusion (AP) of pancreas, spleen, stomach, and intra-portal HCC were calculated. For disease-free patients (normal group), the values were compared among liver segments and among pancreatic and gastric parts. The values were compared between groups and before and after therapy.
RESULTS: No significant differences were found in the normal group except between APFs for liver segments 3 and 5, and fundus and antrum. Mean HAP and APF for the disease group were significantly higher than for the normal group. APF increased after partial splenic embolization or creation of a transjugular intrahepatic portosystemic shunt. HPP increased and AP of intra-portal HCC decreased after successful radiotherapy.
CONCLUSIONS: 320-Detector row CT makes it possible to conduct perfusion measurements of the whole upper abdomen. Our preliminary results suggested that estimated perfusion values have the potential to be used for evaluation of hepatic diseases and therapeutic effects.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22055684     DOI: 10.1016/j.ejrad.2011.10.009

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  13 in total

1.  Shear wave velocity might correlate with portal venous perfusion if correct portal venous perfusion techniques are used.

Authors:  Yoshito Tsushima; Ayako Taketomi-Takahashi
Journal:  J Med Ultrason (2001)       Date:  2019-06-04       Impact factor: 1.314

2.  Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

Authors:  Elisa Almeida Sathler Bretas; Ulysses S Torres; Lucas Rios Torres; Daniel Bekhor; Celso Fernando Saito Filho; Douglas Jorge Racy; Lorenzo Faggioni; Giuseppe D'Ippolito
Journal:  Br J Radiol       Date:  2017-08-22       Impact factor: 3.039

Review 3.  Perfusion CT imaging of the liver: review of clinical applications.

Authors:  Hayri Oğul; Mecit Kantarcı; Berhan Genç; Berhan Pirimoğlu; Neşat Cullu; Yeşim Kızrak; Omer Yılmaz; Nevzat Karabulut
Journal:  Diagn Interv Radiol       Date:  2014 Sep-Oct       Impact factor: 2.630

4.  Hemodynamic Alteration in the Liver in Acute Hepatitis: A Quantitative Evaluation Using Computed Tomographic Perfusion.

Authors:  Akihiro Nishie; Yasuhiro Ushijima; Yukihisa Takayama; Nobuhiro Fujita; Yuichiro Kubo; Keisuke Ishimatsu; Daisuke Tsurumaru; Motoyuki Kohjima; Kousei Ishigami
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

5.  Assessment of renal function in patients with unilateral ureteral obstruction using whole-organ perfusion imaging with 320-detector row computed tomography.

Authors:  Xiang-Ran Cai; Qing-Chun Zhou; Juan Yu; You-Zhen Feng; Zhao-Hui Xian; Wen-Cai Yang; Xu-Kai Mo
Journal:  PLoS One       Date:  2015-04-15       Impact factor: 3.240

6.  Diminished liver microperfusion in Fontan patients: A biexponential DWI study.

Authors:  Hildebrand Dijkstra; Djoeke Wolff; Joost P van Melle; Beatrijs Bartelds; Tineke P Willems; Matthijs Oudkerk; Hans Hillege; Aad P van den Berg; Tjark Ebels; Rolf M F Berger; Paul E Sijens
Journal:  PLoS One       Date:  2017-03-03       Impact factor: 3.240

7.  Intra- and interobserver reproducibility of pancreatic perfusion by computed tomography.

Authors:  Tiago S Garcia; Jean-Luc Engelholm; Michaël Vouche; Vânia N Hirakata; Cristiane B Leitão
Journal:  Sci Rep       Date:  2019-04-15       Impact factor: 4.379

8.  The feasibility of low-concentration contrast and low tube voltage in computed tomography perfusion imaging: an animal study.

Authors:  Yuning Pan; Aiqin Song; Shizhong Bu; Zhaoqian Chen; Qiuli Huang; Aijing Li
Journal:  Biosci Rep       Date:  2018-01-10       Impact factor: 3.840

9.  The clinical application of one-stop examination with 640-slice volume CT for Nutcracker syndrome.

Authors:  Jianguo Zhong; Jianhua Yuan; Vincent Chong; Zhen Wang; Jian Xu; Zhongxiang Ding
Journal:  PLoS One       Date:  2013-09-16       Impact factor: 3.240

10.  Application of dual-source CT perfusion imaging and MRI for the diagnosis of primary liver cancer.

Authors:  Dongwen Zhang; Aixia Xu
Journal:  Oncol Lett       Date:  2017-05-15       Impact factor: 2.967

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.