Literature DB >> 22052070

Contrast-enhanced ultrasonography is more sensitive than grayscale and power Doppler ultrasonography compared to MRI in therapy monitoring of rheumatoid arthritis patients.

S Ohrndorf1, A Hensch, L Naumann, K-G A Hermann, C Scheurig-Münkler, S Meier, G R Burmester, M Backhaus.   

Abstract

PURPOSE: To evaluate wrist and finger joints in patients with rheumatoid arthritis (RA) by grayscale, power Doppler (PD) and contrast-enhanced musculoskeletal ultrasonography (US) and to compare these findings with MRI, clinical (DAS28) and laboratory (ESR; CRP) data.
MATERIALS AND METHODS: US was performed at baseline (t0) and after three, six and twelve (t12) months before and after a change of medical treatment. MRI was carried out at t0 and t12 and used as the reference method. Contrast-enhanced US was used to assess one clinically most affected joint region. Different semiquantitative synovitis scores were calculated by grayscale and PD US.
RESULTS: Contrast-enhanced US results evaluated by enhancement, slope and semi-quantitative assessment significantly correlated to each other, to grayscale US, CRP, as well as to MRI with the highest correlation coefficients for the used contrast-enhanced US modes (r = 0.56, r = 0.55, r = 0.57; each p < 0.05). Sum scores evaluated by grayscale US showed that synovial inflammation in finger joints was detected significantly more frequently in the palmar aspect than on the dorsal side (p = 0.001). Using power Doppler US, the wrists were significantly more inflamed from dorsal than on the palmar side (p = 0.0004). Significant longitudinal correlations between grayscale and power Doppler US scores were detected.
CONCLUSION: Grayscale, power Doppler and contrast-enhanced US are accurate tools for the detection and follow-up of synovitis in RA wrist and finger joints, with contrast-enhanced US being most sensitive compared to MRI. All imaging methods reflected a good response to TNFα blocking therapy. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22052070     DOI: 10.1055/s-0031-1281770

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  12 in total

Review 1.  Doppler US in rheumatic diseases with special emphasis on rheumatoid arthritis and spondyloarthritis.

Authors:  Hüseyin Toprak; Erkan Kılıç; Aslı Serter; Ercan Kocakoç; Salih Özgöçmen
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

2.  Superb microvascular imaging is as sensitive as contrast-enhanced ultrasound for detecting synovial vascularity in rheumatoid arthritis.

Authors:  Xue-Hong Diao; Yan Shen; Lin Chen; Jia Zhan; Liang Fang; Ying-Chun Liu; Yue Chen
Journal:  Quant Imaging Med Surg       Date:  2022-05

Review 3.  A Review of Clinical Applications for Super-resolution Ultrasound Localization Microscopy.

Authors:  Hui-Ming Yi; Matthew R Lowerison; Peng-Fei Song; Wei Zhang
Journal:  Curr Med Sci       Date:  2022-02-15

Review 4.  Musculoskeletal ultrasonography in patients with rheumatoid arthritis.

Authors:  Sarah Ohrndorf; Marina Backhaus
Journal:  Nat Rev Rheumatol       Date:  2013-05-21       Impact factor: 20.543

5.  Assessment of carotid plaque neovascularization by contrast-enhanced ultrasound and high sensitivity C-reactive protein test in patients with acute cerebral infarction: a comparative study.

Authors:  Rong Xu; Xiaohua Yin; Weixin Xu; Lin Jin; Min Lu; Yingchun Wang
Journal:  Neurol Sci       Date:  2016-03-28       Impact factor: 3.307

Review 6.  [CEUS-application possibilities in the musculoskeletal system].

Authors:  M Jäschke; M-A Weber; C Fischer
Journal:  Radiologe       Date:  2018-06       Impact factor: 0.635

Review 7.  Ultrasound in sports medicine: relevance of emerging techniques to clinical care of athletes.

Authors:  Eugene Sun Yim; Gianmichael Corrado
Journal:  Sports Med       Date:  2012-08-01       Impact factor: 11.928

8.  Application of high frequency color Doppler ultrasound in the monitoring of rheumatoid arthritis treatment.

Authors:  Guimin Zheng; Lei Wang; Xiuchuan Jia; Fang Li; Yonglong Yan; Zhibo Yu; Li Li; Qun Wei; Fengxiao Zhang
Journal:  Exp Ther Med       Date:  2014-10-01       Impact factor: 2.447

Review 9.  Role of Contrast-enhanced Ultrasound in the Evaluation of Inflammatory Arthritis.

Authors:  Chen-Yang Zhao; Yu-Xin Jiang; Jian-Chu Li; Zhong-Hui Xu; Qing Zhang; Na Su; Meng Yang
Journal:  Chin Med J (Engl)       Date:  2017-07-20       Impact factor: 2.628

10.  Musculoskeletal ultrasound in hemophilia: Results and recommendations from a global survey and consensus meeting.

Authors:  Nihal Bakeer; Saunya Dover; Paul Babyn; Brian M Feldman; Annette von Drygalski; Andrea S Doria; Danial M Ignas; Audrey Abad; Cindy Bailey; Ian Beggs; Eric Y Chang; Amy Dunn; Sharon Funk; Sridhar Gibikote; Nicholas Goddard; Pamela Hilliard; Shyamkumar N Keshava; Rebecca Kruse-Jarres; Yingjia Li; Sébastien Lobet; Marilyn Manco-Johnson; Carlo Martinoli; James S O'Donnell; Olympia Papakonstantinou; Helen Pergantou; Pradeep Poonnoose; Felipe Querol; Alok Srivastava; Bruno Steiner; Karen Strike; Merel Timmer; Pascal N Tyrrell; Logi Vidarsson; Victor S Blanchette
Journal:  Res Pract Thromb Haemost       Date:  2021-07-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.