Impact of calibration on estimates of central blood pressures.

T K Soender1, L M Van Bortel, J E Møller, J Lambrechtsen, J Hangaard, K Egstrup.   

Abstract

Using the Sphygmocor device it is recommended that the radial pressure wave is calibrated for brachial systolic blood pressure (SBP) and diastolic blood pressure (DBP). However it has been suggested that brachial-to-radial pressure amplification causes underestimation of central blood pressures (BPs) using this calibration. In the present study we examined if different calibrations had an impact on estimates of central BPs and on the clinical interpretation of our results. On the basis of ambulatory BP measurements, patients were categorized into patients with controlled, uncontrolled or resistant hypertension. We first calibrated the radial pressure wave as recommended and afterwards recalibrated the same pressure wave using brachial DBP and calculated mean arterial pressure. Recalibration of the pressure wave generated significantly higher estimates of central SBP (P=0.0003 and P<0.0001 at baseline and P=0.0001 and P=0.0002 after 6 months). Using recommended calibration we found a significant change in central SBP in both treatment groups (P=0.05 and P=0.01), however, after recalibrating significance was lost in patients with resistant hypertension (P=0.15). We conclude that calibration with DBP and mean arterial pressure produces higher estimates of central BPs than recommended calibration. The present study also shows that this difference between the two calibration methods can produce more than a systematic error and has an impact on interpretation of clinical results.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22048713     DOI: 10.1038/jhh.2011.97

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  3 in total

1.  Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Authors:  Willem J Verberk; Hao-Min Cheng; Li-Chih Huang; Chia-Ming Lin; Yao-Pin Teng; Chen-Huan Chen
Journal:  Pulse (Basel)       Date:  2016-02-12

2.  Brachial-to-radial systolic blood pressure amplification in patients with type 2 diabetes mellitus.

Authors:  R E D Climie; D S Picone; M A Keske; J E Sharman
Journal:  J Hum Hypertens       Date:  2015-10-08       Impact factor: 3.012

3.  Non-invasively estimated end-systolic elastance in patients with resistant hypertension and type 2 diabetes mellitus.

Authors:  Trine K Soender; Tine De Backer
Journal:  Heart Vessels       Date:  2013-06-02       Impact factor: 2.037

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.