Statistical evaluation of photon count rate data for nanoscale particle measurement in wastewaters.

Josh Smeraldi1, Rajagopalan Ganesh, Jana Safarik, Diego Rosso.   

Abstract

The dynamic light scattering (DLS) technique can detect the concentration and size distribution of nanoscale particles in aqueous solutions by analyzing photon interactions. This study evaluated the applicability of using photon count rate data from DLS analyses for measuring levels of biogenic and manufactured nanoscale particles in wastewater. Statistical evaluations were performed using secondary wastewater effluent and a Malvern Zetasizer. Dynamic light scattering analyses were performed equally by two analysts over a period of two days using five dilutions and twelve replicates for each dilution. Linearity evaluation using the sixty sample analysis yielded a regression coefficient R(2) = 0.959. The accuracy analysis for various dilutions indicated a recovery of 100 ± 6%. Precision analyses indicated low variance coefficients for the impact of analysts, days, and within sample error. The variation by analysts was apparent only in the most diluted sample (intermediate precision ~12%), where the photon count rate was close to the instrument detection limit. The variation for different days was apparent in the two most concentrated samples, which indicated that wastewater samples must be analyzed for nanoscale particle measurement within the same day of collection. Upon addition of 10 mg l(-1) of nanosilica to wastewater effluent samples, the measured photon count rates were within 5% of the estimated values. The results indicated that photon count rate data can effectively complement various techniques currently available to detect nanoscale particles in wastewaters.

Mesh:

Substances:

Year:  2011        PMID: 22048710     DOI: 10.1039/c1em10237k

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  2 in total

Review 1.  Nanoparticle counting: towards accurate determination of the molar concentration.

Authors:  Jing Shang; Xiaohu Gao
Journal:  Chem Soc Rev       Date:  2014-08-07       Impact factor: 54.564

2.  An Update to Dialysis-Based Drug Release Testing-Data Analysis and Validation Using the Pharma Test Dispersion Releaser.

Authors:  Marc-Phillip Mast; Harshvardhan Modh; Julian Knoll; Elena Fecioru; Matthias G Wacker
Journal:  Pharmaceutics       Date:  2021-11-25       Impact factor: 6.321

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.