Literature DB >> 22047028

Development of a multilevel approach for the evaluation of nanomaterials' toxicity.

Luca Galluzzi1, Laura Chiarantini, Elena Pantucci, Rosa Curci, Jacqueline Merikhi, Helga Hummel, Peter K Bachmann, Elisabetta Manuali, Giovanni Pezzotti, Mauro Magnani.   

Abstract

AIM: To develop a multilevel approach that includes different toxicity tests and gene-expression studies for toxicity evaluation of engineered nanomaterials developed for biomedical applications. MATERIALS &
METHODS: K-562, MCF-7 and U-937 human-derived cell lines were used as models for in vitro toxicity tests. These tests included viability assays (3-[4,5-dimethylthiazol-2-yl]-5-[3-carboxymethoxyphenyl]-2-[4-sulfophenyl]-2H-tetrazolium [MTS] assay); evaluation of apoptosis/necrosis by propidium iodide staining and DNA laddering assay; evaluation of mitochondrial toxicity (5,5´,6,6´-tetrachloro-1,1´,3,3´-tetraethyl-benzimidazolcarbocyanine iodide [JC-1] assay); transmission electron microscopy analysis and gene expression analysis by DNA microarray. For in vivo toxicity evaluation, Swiss mice were used for monitoring acute or chronic effects. Two superparamagnetic contrast agents approved for human use (Resovist and Primovist) and two new lanthanide-based luminescent nanoparticles were tested. RESULTS & DISCUSSION: The nanomaterials approved for human use did not show significant toxicities in our assays. Toxicity studies performed on lanthanide-based nanoparticles (EDTA120 and EDTA120D) complexed with the chelating agent EDTA revealed that these nanomaterials induced necrosis in U-937 and K-562 cells while no toxicity was observed in MCF-7 cells. Moreover, no in vivo effects have been observed. The comparative analysis of the nanomaterials and their separated components showed that the toxicity in U-937 and K-562 cells was mainly due to the presence of EDTA.
CONCLUSION: The multilevel approach proved to be useful for nanomaterial toxicity characterization. In particular, for the lanthanide-based nanoparticles tested in this work, the EDTA was identified as the main cause of the toxicity in vitro, suggesting a possible applicability of these nanoparticle suspensions for in vivo optical imaging.

Entities:  

Mesh:

Year:  2011        PMID: 22047028     DOI: 10.2217/nnm.11.106

Source DB:  PubMed          Journal:  Nanomedicine (Lond)        ISSN: 1743-5889            Impact factor:   5.307


  2 in total

1.  Plasma & Microwaves as Greener Options for Nanodiamond Purification: Insight Into Cytocompatibility.

Authors:  Dimitar P Mitev; Amir M Alsharabasy; Liam Morrison; Sebastian Wittig; Christof Diener; Abhay Pandit
Journal:  Front Bioeng Biotechnol       Date:  2021-06-30

2.  Nanomaterials toxicity and cell death modalities.

Authors:  Daniela De Stefano; Rosa Carnuccio; Maria Chiara Maiuri
Journal:  J Drug Deliv       Date:  2012-12-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.