Literature DB >> 22045693

Evaluation of rotational control and forces generated during first-order archwire deflections: a comparison of self-ligating and conventional brackets.

Robert E Pesce1, Flavio Uribe2, Nandakumar Janakiraman1, William P Neace3, Donald R Peterson4, Ravindra Nanda5.   

Abstract

The purpose of this study was to compare the activation and deactivation forces generated during first-order archwire deflections when different sizes and types of NiTi wires are paired with conventional and self-ligating brackets (SLBs) and to evaluate the rotational control between these same archwire and bracket combinations. Four maxillary premolar SLBs (Damon 3MX, SmartClip, Carriere, and In-Ovation R) and one conventional twin bracket (Victory) were paired with seven archwires [0.014, 0.016, 0.018, 0.016 × 0.022 Ultra Therm (thermal A f 80-90°F), 0.016, 0.018 SPEED Supercable, and 0.017 × 0.025 Turbo]. A cantilever test design was used and 10 trials per bracket/archwire combination were performed. Load/deflection data were captured over 4 mm fi rst-order archwire deflections. Forces generated were compared across all bracket/archwire combinations. Among thermal archwires, for a given deflection, forces increased with increasing archwire size. Supercable archwires displayed less force than their same size thermal counterparts. The Turbo archwire generated force values in between those of 0.016 and 0.018 thermal archwires. Rotational control improved with increasing wire dimensions and for a given archwire size. Rotational control among brackets generally ranked as follows: In-Ovation R > SmartClip > Carriere and Damon 3MX.

Mesh:

Year:  2011        PMID: 22045693     DOI: 10.1093/ejo/cjr119

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets.

Authors:  Manoela Fávaro Francisconi; Guilherme Janson; José Fernando Castanha Henriques; Karina Maria Salvatore de Freitas
Journal:  J Appl Oral Sci       Date:  2016 Sep-Oct       Impact factor: 2.698

2.  Evaluation of the force generated by gradual deflection of 0.016-inch NiTi and stainless steel orthodontic wires in self-ligating metallic and esthetic brackets.

Authors:  Manoela-Fávaro Francisconi; Guilherme Janson; José-Fernando-Castanha Henriques; Karina-Maria-Salvatore Freitas; Paulo-Afonso-Silveira Francisconi
Journal:  J Clin Exp Dent       Date:  2019-05-01

3.  Clinical effects with customized brackets and CAD/CAM technology: a prospective controlled study.

Authors:  Julia Hegele; Lena Seitz; Cora Claussen; Uwe Baumert; Hisham Sabbagh; Andrea Wichelhaus
Journal:  Prog Orthod       Date:  2021-12-06       Impact factor: 2.750

4.  Class I malocclusion with severe double protrusion treated with first premolars extraction.

Authors:  Ricardo Moresca
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

5.  Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study.

Authors:  Huizhong Chen; Bing Han; Tianmin Xu
Journal:  Korean J Orthod       Date:  2018-12-19       Impact factor: 1.372

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.