Literature DB >> 22043858

Artificial microvascular network: a new tool for measuring rheologic properties of stored red blood cells.

Jennie M Burns1, Xiaoxi Yang, Omid Forouzan, Jose M Sosa, Sergey S Shevkoplyas.   

Abstract

BACKGROUND: The progressive deterioration of red blood cell (RBC) rheologic properties during refrigerated storage may reduce the clinical efficacy of transfusion of older units. STUDY DESIGN AND METHODS: This article describes the development of a microfluidic device designed to test the rheologic properties of stored RBCs by measuring their ability to perfuse an artificial microvascular network (AMVN) comprised of capillary-size microchannels arranged in a pattern inspired by the real microvasculature. In the AMVN device, the properties of RBCs are evaluated by passing a 40% hematocrit suspension of RBCs through the network and measuring the overall perfusion rate.
RESULTS: The sensitivity of the AMVN device to the storage-induced change in rheologic properties of RBCs was tested using five prestorage leukoreduced RBC units stored in AS-1 for 41 days. The AMVN perfusion rate for stored RBCs was 26 ± 4% (19%-30%) lower than for fresh RBCs. Washing these stored RBCs in saline improved their performance by 41 ± 6% (the AMVN perfusion rate for washed stored RBCs was still 15 ± 2% lower than for fresh RBCs).
CONCLUSIONS: The measurements performed using the AMVN device confirm a significant decline in the rheologic properties of RBCs in units nearing expiration and demonstrate the sensitivity of the device to these storage-induced changes. The AMVN device may be useful for testing the effect of new storage conditions, additive solutions, and rejuvenation strategies on the rheologic properties of stored RBCs in vitro.
© 2011 American Association of Blood Banks.

Entities:  

Mesh:

Year:  2011        PMID: 22043858     DOI: 10.1111/j.1537-2995.2011.03418.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  19 in total

1.  Deterioration of red blood cell mechanical properties is reduced in anaerobic storage.

Authors:  Jennie M Burns; Tatsuro Yoshida; Larry J Dumont; Xiaoxi Yang; Nathaniel Z Piety; Sergey S Shevkoplyas
Journal:  Blood Transfus       Date:  2015-11-27       Impact factor: 3.443

2.  Effect of osmolality on erythrocyte rheology and perfusion of an artificial microvascular network.

Authors:  Walter H Reinhart; Nathaniel Z Piety; Jeroen S Goede; Sergey S Shevkoplyas
Journal:  Microvasc Res       Date:  2015-02-07       Impact factor: 3.514

3.  Quantifying morphological heterogeneity: a study of more than 1 000 000 individual stored red blood cells.

Authors:  N Z Piety; S C Gifford; X Yang; S S Shevkoplyas
Journal:  Vox Sang       Date:  2015-04-20       Impact factor: 2.144

4.  Influence of feeding hematocrit and perfusion pressure on hematocrit reduction (Fåhraeus effect) in an artificial microvascular network.

Authors:  Walter H Reinhart; Nathaniel Z Piety; Sergey S Shevkoplyas
Journal:  Microcirculation       Date:  2017-11       Impact factor: 2.628

Review 5.  Blood rheology biomarkers in sickle cell disease.

Authors:  Madeleine Lu; Minke Ae Rab; Sergey S Shevkoplyas; Vivien A Sheehan
Journal:  Exp Biol Med (Maywood)       Date:  2020-01-16

6.  Shape matters: the effect of red blood cell shape on perfusion of an artificial microvascular network.

Authors:  Nathaniel Z Piety; Walter H Reinhart; Patrick H Pourreau; Rajaa Abidi; Sergey S Shevkoplyas
Journal:  Transfusion       Date:  2015-12-29       Impact factor: 3.157

7.  Influence of red blood cell aggregation on perfusion of an artificial microvascular network.

Authors:  Walter H Reinhart; Nathaniel Z Piety; Sergey S Shevkoplyas
Journal:  Microcirculation       Date:  2017-07       Impact factor: 2.628

8.  Centrifugation-free washing: A novel approach for removing immunoglobulin A from stored red blood cells.

Authors:  Eszter Vörös; Nathaniel Z Piety; Briony C Strachan; Madeleine Lu; Sergey S Shevkoplyas
Journal:  Am J Hematol       Date:  2018-01-25       Impact factor: 10.047

9.  Washing stored red blood cells in an albumin solution improves their morphologic and hemorheologic properties.

Authors:  Walter H Reinhart; Nathaniel Z Piety; Jeremy W Deuel; Asya Makhro; Thomas Schulzki; Nikolay Bogdanov; Jeroen S Goede; Anna Bogdanova; Rajaa Abidi; Sergey S Shevkoplyas
Journal:  Transfusion       Date:  2015-03-06       Impact factor: 3.157

10.  The relationship between red blood cell deformability metrics and perfusion of an artificial microvascular network.

Authors:  Jose M Sosa; Nathan D Nielsen; Seth M Vignes; Tanya G Chen; Sergey S Shevkoplyas
Journal:  Clin Hemorheol Microcirc       Date:  2014       Impact factor: 2.375

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.