Literature DB >> 22042458

Influence of topographical features on the fluoride corrosion of Ni-Ti orthodontic archwires.

C Abalos1, A Paúl, A Mendoza, E Solano, F J Gil.   

Abstract

Different manufacturing processes of Ni-Ti archwires respond differently to corrosion due to the surface conditions involved. In this study, several topographical features and their influence upon fluoride corrosion were studied. Four topographies (smooth, dimple, scratch, and crack) according to the main surface defect were characterized (n = 40). Static corrosion tests were performed in artificial saliva with fluorated prophylactic gel (12500 ppm) for 28 days. The surface was characterized by SEM and laser confocal microscopy. Standard electrochemical corrosion (open circuit potential, corrosion potential and corrosion current density) was performed. Statistical analysis was carried out using the ANOVA test (α ≤ 0.05). An increase was observed in the surface defects and/or roughness of the cracked and scratched surfaces. These defects produced an important increase in corrosion behavior. The best surfaces for the orthodontic archwires were the smooth and dimpled surfaces, respectively. The increase in defects was independent of roughness. Manufacturing processes that produce surface cracks should be avoided in orthodontic applications.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22042458     DOI: 10.1007/s10856-011-4460-y

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  31 in total

1.  The NiTi superelastic alloy application to the dentistry field.

Authors:  L Torrisi
Journal:  Biomed Mater Eng       Date:  1999       Impact factor: 1.300

2.  On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility.

Authors:  Mohammed Es-Souni; Martha Es-Souni; Helge Fischer-Brandies
Journal:  Biomaterials       Date:  2002-07       Impact factor: 12.479

3.  Ion release from NiTi orthodontic wires in artificial saliva with various acidities.

Authors:  Her-Hsiung Huang; Yu-Hui Chiu; Tzu-Hsin Lee; Shih-Ching Wu; Hui-Wen Yang; Kuo-Hsiung Su; Chii-Chih Hsu
Journal:  Biomaterials       Date:  2003-09       Impact factor: 12.479

4.  Influence of fluoridated mouthwashes on corrosion resistance of orthodontics wires.

Authors:  Nicolas Schiff; Brigitte Grosgogeat; Michèle Lissac; Francis Dalard
Journal:  Biomaterials       Date:  2004-08       Impact factor: 12.479

5.  Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity.

Authors:  Her-Hsiung Huang
Journal:  J Biomed Mater Res A       Date:  2005-09-15       Impact factor: 4.396

6.  Stress corrosion cracking of NiTi in artificial saliva.

Authors:  Jianqiu Wang; Nianxing Li; Guangbin Rao; En-Hou Han; Wei Ke
Journal:  Dent Mater       Date:  2006-02-08       Impact factor: 5.304

Review 7.  A review of contemporary archwires: their properties and characteristics.

Authors:  R P Kusy
Journal:  Angle Orthod       Date:  1997       Impact factor: 2.079

8.  Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires.

Authors:  Mary P Walker; Richard J White; Katherine S Kula
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-06       Impact factor: 2.650

9.  Galvanic corrosion between orthodontic wires and brackets in fluoride mouthwashes.

Authors:  Nicolas Schiff; Mickaël Boinet; Laurent Morgon; Michèle Lissac; Francis Dalard; Brigitte Grosgogeat
Journal:  Eur J Orthod       Date:  2006-01-20       Impact factor: 3.075

10.  An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires.

Authors:  N P Hunt; S J Cunningham; C G Golden; M Sheriff
Journal:  Angle Orthod       Date:  1999-10       Impact factor: 2.079

View more
  1 in total

1.  NiTi superelastic orthodontic archwires with polyamide coating.

Authors:  L A Bravo; A González de Cabañes; J M Manero; E Rúperez; F Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2013-10-24       Impact factor: 3.896

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.