Literature DB >> 22040746

The potential application of a poly(3,4-ethylenedioxythiopene) modified platinum DNA biosensor in mutation analysis.

Yesong Gu1, Meng-Tsun Lai.   

Abstract

In this study, we have fabricated a label free DNA biosensor by modifying the platinum wire with electrochemically synthesized poly(3,4-ethylenedioxythiopene) and poly(p-aminobenzoic acid). A designed single-strand DNA oligo was immobilized with the carboxyl group of poly(p-aminobenzoic acid) and served as the probe, a target DNA was then hybridized with the probe under a proper condition. Differential pulse voltammetry was performed to characterize the hybridization efficiency in the presence of daunorubicin hydrochloride that was able to be intercalated into the hybridized double-strand DNA and possessed the redox activity. Our results revealed a satisfied linear correlation between the peak current of differential pulse voltammetry and the concentration of complementary target DNA. On the other hand, the mismatches between the target- and probe-DNA caused a significant reduction of electrochemical response, in which was correlated with the amount of mismatched base pairs, therefore the current DNA biosensor had potential applications not only in DNA quantification but also in mutation detection for clinical diagnostics and laboratory applications.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22040746     DOI: 10.1016/j.bios.2011.10.014

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Molecular Assembly of a Durable HRP-AuNPs/PEDOT:BSA/Pt Biosensor with Detailed Characterizations.

Authors:  Fangcheng Xu; Shuaibin Ren; Jiansin Li; Xiang Bi; Yesong Gu
Journal:  Sensors (Basel)       Date:  2018-06-05       Impact factor: 3.576

2.  Fabrication of an Extremely Cheap Poly(3,4-ethylenedioxythiophene) Modified Pencil Lead Electrode for Effective Hydroquinone Sensing.

Authors:  Jian-Yu Lu; Yu-Sheng Yu; Tung-Bo Chen; Chiung-Fen Chang; Sigitas Tamulevičius; Donats Erts; Kevin C-W Wu; Yesong Gu
Journal:  Polymers (Basel)       Date:  2021-01-22       Impact factor: 4.329

3.  A Novel Conductive Poly(3,4-ethylenedioxythiophene)-BSA Film for the Construction of a Durable HRP Biosensor Modified with NanoAu Particles.

Authors:  Fangcheng Xu; Shuaibin Ren; Yesong Gu
Journal:  Sensors (Basel)       Date:  2016-03-15       Impact factor: 3.576

4.  Quantification of DNA by a Thermal-Durable Biosensor Modified with Conductive Poly(3,4-ethylenedioxythiophene).

Authors:  Yesong Gu; Po-Yuan Tseng; Xiang Bi; Jason H C Yang
Journal:  Sensors (Basel)       Date:  2018-10-30       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.