Literature DB >> 22040354

Disinfection of bacterially contaminated hydrophilic PVS impression materials.

Emad Wadie Estafanous1, Charles John Palenik, Jeffrey A Platt.   

Abstract

PURPOSE: This study evaluated disinfection of bacterially contaminated hydrophilic polyvinylsiloxane (PVS) and polyether impressions.
MATERIALS AND METHODS: Four light-bodied PVS (Examix, Genie, Take 1, Aquasil) and one polyether (Impregum) impression materials were evaluated using three disinfectants (EcoTru [EnviroSystems], ProSpray [Certol], and bleach [diluted 1:9]) as spray and immersion disinfections for 10-minute exposures. Pseudomonas aeruginosa ATCC 15442, Salmonella choleraesius ATCC 10708, and Staphylococcus aureus ATCC 6538 was the microbial challenge. Test specimens were prepared using aluminum molds with ten tapered cones. Mucin covered each cone, followed by 0.01 mL of each bacterium. Impressions were made using low viscosity impression material that was injected over the cones and filled custom trays. One-half of the impressions were spray disinfected, while the others underwent immersion disinfection. Trays that were contaminated but not disinfected served as positive controls, while those not bacterially contaminated or disinfected served as negative controls. The impressions were poured with Silky Rock Die Stone, and after setting, two cones were placed within a sterile capsule and triturated into powder. Four milliliters of TRIS buffer (0.05 M, pH 7.0) containing sodium thiosulfate (0.0055% w/v) were poured in each tube. After mixing, the solution was serially diluted and spread-plated onto selective agars. After incubation, colony counting occurred.
RESULTS: No viable bacteria transferred to casts from either spray- or immersion-disinfected impressions. Negative controls produced no microbial colonies. Positive controls produced on average 3.35 × 10(5) bacterial cells.
CONCLUSION: Results suggest the methods used could disinfect contaminated impression materials. Microbial transfer from nondisinfected impressions to cones approached 33.5%.
© 2011 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22040354     DOI: 10.1111/j.1532-849X.2011.00788.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

1.  Evaluation of setting time, tear strength, dimensional stability and antimicrobial property of silver and titanium nanoparticles incorporated elastomeric impression material.

Authors:  Kapoor Abhijeet; J Brintha Jei; K Murugesan; B Muthukumar
Journal:  J Oral Biol Craniofac Res       Date:  2022-07-19

2.  3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions.

Authors:  Kuei-Ling Hsu; Abdulrahman A Balhaddad; Isadora Martini Garcia; Fabrício Mezzomo Collares; Vineet Dhar; Louis DePaola; Mary Anne Melo
Journal:  Saudi Dent J       Date:  2020-12-10

Review 3.  Disinfection Procedures and Their Effect on the Microorganism Colonization of Dental Impression Materials: A Systematic Review and Meta-Analysis of In Vitro Studies.

Authors:  Louis Hardan; Rim Bourgi; Carlos Enrique Cuevas-Suárez; Monika Lukomska-Szymanska; Elizabeth Cornejo-Ríos; Vincenzo Tosco; Riccardo Monterubbianesi; Sara Mancino; Ammar Eid; Davide Mancino; Naji Kharouf; Youssef Haikel
Journal:  Bioengineering (Basel)       Date:  2022-03-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.