Literature DB >> 22038017

Interlaboratory evaluation of trace element determination in workplace air filter samples by inductively coupled plasma mass spectrometry.

Kevin Ashley1, Stanley A Shulman, Michael J Brisson, Alan M Howe.   

Abstract

Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter(-1), with three different filter loadings denoted "Low", "Medium" and "High". Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter(-1). Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22038017      PMCID: PMC4671195          DOI: 10.1039/c1em10695c

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  7 in total

Review 1.  Industrial hygiene chemistry: keeping pace with rapid change in the workplace.

Authors:  W M Draper; K Ashley; C R Glowacki; P R Michael
Journal:  Anal Chem       Date:  1999-06-15       Impact factor: 6.986

2.  Development of an international standard for the determination of metals and metalloids in workplace air using ICP-AES: evaluation of sample dissolution procedures through an interlaboratory trial.

Authors:  O T Butler; A M Howe
Journal:  J Environ Monit       Date:  1999-02

3.  Evaluation of a standardized method for determining soluble silver in workplace air samples.

Authors:  Pamela L Drake; A Dale Marcy; Kevin Ashley
Journal:  J Environ Monit       Date:  2005-10-24

Review 4.  The performance of laboratories analysing heavy metals in the Workplace Analysis Scheme for Proficiency (WASP).

Authors:  Peter R Stacey
Journal:  Ann Occup Hyg       Date:  2006-01-24

5.  Sources of contamination and remedial strategies in the multi-elemental trace analysis laboratory.

Authors:  Ilia Rodushkin; Emma Engström; Douglas C Baxter
Journal:  Anal Bioanal Chem       Date:  2010-01       Impact factor: 4.142

6.  Summary of the NIOSH guidelines for air sampling and analytical method development and evaluation.

Authors:  E R Kennedy; T J Fischbach; R Song; P M Eller; S A Shulman
Journal:  Analyst       Date:  1996-09       Impact factor: 4.616

7.  Trace elemental analysis of airborne particulate matter using dynamic reaction cell inductively coupled plasma-mass spectrometry: application to monitoring episodic industrial emission events.

Authors:  K Suresh Kumar Danadurai; Shankararaman Chellam; Cin-Ty Lee; Matthew P Fraser
Journal:  Anal Chim Acta       Date:  2010-11-26       Impact factor: 6.558

  7 in total
  6 in total

1.  Preliminary studies on the use of acid-soluble cellulose acetate internal capsules for workplace metals sampling and analysis.

Authors:  Martin Harper; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

2.  Calibration Approaches for Measurement of Aerosol Multielemental Concentration using Spark Emission Spectroscopy.

Authors:  L Zheng; P Kulkarni; D D Dionysiou
Journal:  J Anal At Spectrom       Date:  2018       Impact factor: 4.351

3.  NIOSH Manual of Analytical Methods 5th Edition and Harmonization of Occupational Exposure Monitoring.

Authors:  Kevin Ashley
Journal:  Gefahrst Reinhalt Luft       Date:  2015       Impact factor: 0.323

4.  Interlaboratory evaluation of cellulosic acid-soluble internal air sampling capsules for multi-element analysis.

Authors:  Ronnee N Andrews; H Amy Feng; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

5.  Acid-soluble internal capsules for closed-face cassette elemental sampling and analysis of workplace air.

Authors:  Martin Harper; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

6.  Preparation and certification of two new bulk welding fume reference materials for use in laboratories undertaking analysis of occupational hygiene samples.

Authors:  Owen Butler; Darren Musgrove; Peter Stacey
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

  6 in total