| Literature DB >> 22036639 |
Hong Chen1, Andrew A Brayman, Wayne Kreider, Michael R Bailey, Thomas J Matula.
Abstract
High-speed photomicrography was used to study the translational dynamics of single microbubbles in microvessels of ex vivo rat mesenteries. The microbubbles were insonated by a single 2 μs ultrasound pulse with a center frequency of 1 MHz and peak negative pressures spanning the range of 0.8-4 MPa. The microvessel diameters ranged from 10-80 μm. The high-speed image sequences show evidence of ultrasound-activated microbubble translation away from the nearest vessel wall; no microbubble showed a net translation toward the nearest vessel wall. Microbubble maximum translation displacements exceeded 20 μm. Microjets with the direction of the jets identifiable were also observed; all microjets appear to have been directed away from the nearest vessel wall. These observations appear to be characteristic of a strong coupling between ultrasound-driven microbubbles and compliant microvessels. Although limited to mesenteric tissues, these observations provide an important step in understanding the physical interactions between microbubbles and microvessels. Published by Elsevier Inc.Entities:
Mesh:
Year: 2011 PMID: 22036639 PMCID: PMC3223323 DOI: 10.1016/j.ultrasmedbio.2011.09.013
Source DB: PubMed Journal: Ultrasound Med Biol ISSN: 0301-5629 Impact factor: 2.998