| Literature DB >> 22030971 |
Thays Bueno Takeda1, Daniela Gil.
Abstract
UNLABELLED: Otoacoustic Emissions are generated by the cochlea in response to sound stimuli. They can be generated by clicks or specific frequency stimuli, such as tone pips. This is a quick and objective test with several applications.Entities:
Mesh:
Year: 2011 PMID: 22030971 PMCID: PMC9443748 DOI: 10.1590/s1808-86942011000500014
Source DB: PubMed Journal: Braz J Otorhinolaryngol ISSN: 1808-8686
Descriptive measures for the parameters response, reproducibility, stability, and OAEs with clicks and tone pips at 2,000 Hz and 4,000 Hz, for both ears and different levels of hearing loss.
| Descriptive | Mean | Median | Standard Deviation | Q1 | Q3 | N | CI | |
|---|---|---|---|---|---|---|---|---|
| Click | 10.70 | 9.2 | 4.22 | 7.0 | 14.3 | 22 | 1.76 | |
| Resp. | Tone 2k | 7.38 | 6.5 | 2.82 | 5.4 | 8.4 | 22 | 1.18 |
| Tone 4k | 6.49 | 5.7 | 2.47 | 5.0 | 7.1 | 16 | 1.21 | |
| Click | 13.6% | 7.5% | 43.9% | -24.5% | 59.3% | 64 | 10.7% | |
| Repro. | Tone 2k | 4.0% | 5.0% | 30.4% | -21.5% | 24.0% | 64 | 7.5% |
| Tone 4k | -6.6% | -12.0% | 30.7% | -28.3% | 17.0% | 64 | 7.5% | |
| Click | 86.2% | 88.0% | 9.0% | 76.8% | 94.0% | 64 | 2.2% | |
| Stab. | Tone 2k | 82.9% | 85.0% | 12.1% | 79.0% | 89.0% | 64 | 3.0% |
| Tone 4k | 85.0% | 84.0% | 6.3% | 80.0% | 91.0% | 64 | 1.6% | |
| Click | 78.05 | 78 | 2.31 | 76 | 79 | 64 | 0.56 | |
| Stim. | Tone 2k | 78.98 | 79 | 2.49 | 77.75 | 80 | 64 | 0.61 |
| Tone 4k | 80.52 | 81 | 2.52 | 79 | 82 | 64 | 0.62 | |
Key: Resp: Response
Repro: Reproducibility
Stab: Stability
Stim: Stimulus
Q1: 1st quartile
Q3: 3rd quartile
N: Number of total OAEs
CI: Confidence interval
Result of OAEs evoked by clicks and tone pips at 2,000 Hz and 4,000 Hz, in both ears and according to the degrees of hearing loss.
| Click | Tone Pip 2kHz | Tone Pip 4kHz | |||||
|---|---|---|---|---|---|---|---|
| N | % | N | % | N | % | ||
| RE | 11 | 34.4% | 11 | 34.4% | 3 | 9.4% | |
| Present | LE | 11 | 34.4% | 11 | 34.4% | 4 | 12.5% |
| RE | 21 | 65.6% | 21 | 65.6% | 29 | 90.6% | |
| Absent | LE | 21 | 65.6% | 21 | 65.6% | 28 | 87.5% |
Key: RE: right ear. LE: left ear.
P-values of Table 2.
| Click | ||
|---|---|---|
| tone pip 2kHz | 1.000 | |
| RE | tone pip 4kHz | 0.016* |
| tone pip 2kHz | 1.000 | |
| LE | tone pip 4kHz | 0.039* |
Significance: p < 0.05
Key: RE: right ear. LE: left ear.
Results of OAEs evoked by clicks and tone pips at 2,000 Hz and 4,000 Hz, according to sex.
| Female | Male | |||||
|---|---|---|---|---|---|---|
| Gender | N | % | N | % | p-value | |
| Absent | 20 | 100.0% | 22 | 50.0% | ||
| Click | Present | 0 | 0.0% | 22 | 50.0% | <0.001* |
| Absent | 18 | 90.0% | 24 | 54.5% | ||
| Tone 2k | Present | 2 | 10.0% | 20 | 45.5% | 0.006* |
| Absent | 17 | 85.0% | 40 | 90.9% | ||
| Tone 4k | Present | 3 | 15.0% | 4 | 9.1% | 0.483 |
Significance p < 0.05.
Results of OAEs evoked by clicks and tone pips at 2,000 Hz and 4,000 Hz according to the degree of hearing loss.
| Mild | Moderate | |||||
|---|---|---|---|---|---|---|
| Loss | N | % | N | % | ||
| Absent | 0 | 0.0% | 42 | 91.3% | ||
| Click | Present | 18 | 100.0% | 4 | 8.7% | <0.001* |
| Absent | 0 | 0.0% | 42 | 91.3% | ||
| Tone 2k | Present | 18 | 100.0% | 4 | 8.7% | <0.001* |
| Absent | 16 | 88.9% | 41 | 89.1% | ||
| Tone 4k | Present | 2 | 11.1% | 5 | 10.9% | 0.978 |
Significance p < 0.05