AIMS: Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients. METHODS AND RESULTS:Eighty-four diabetic patients (60.8 ± 9.1 years, 76.2% male) were randomised to either the DEB SeQuent Please or the DES Taxus Liberté to compare the 9-month clinical and angiographic outcome of PCI in native coronary arteries. Comparing the DEB vs. the DES the 9-month results (follow-up DEB 39/45 [86.7%], DES 36/39 [92.3%]) are statistically not different at the 0.05 level for the primary endpoint of in-segment (0.37 ± 0.59 mm vs. 0.35 ± 0.63 mm) and in-stent (0.51 ± 0.61 mm vs. 0.53 ± 0.67 mm) late lumen loss, overall and cardiac deaths (2/45 [4.4%] and 3/45 [6.7%] vs. 0), target lesion revascularisation (3/45 [8.9%] vs. 4/39 [10.3%]), the total MACE rate (6/45 [13.3%] vs. 6/39 [15.4%]), and the event free survival after 10.2 ± 3.8 months (Kaplan-Meier analysis, p<0.80, log rank test). CONCLUSIONS: The clinical and angiographic outcome of the combination of the drug-eluting balloon SeQuent Please with a cobalt chromium stent compared to the drug eluting Taxus stent are similar.
RCT Entities:
AIMS: Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients. METHODS AND RESULTS: Eighty-four diabeticpatients (60.8 ± 9.1 years, 76.2% male) were randomised to either the DEB SeQuent Please or the DES Taxus Liberté to compare the 9-month clinical and angiographic outcome of PCI in native coronary arteries. Comparing the DEB vs. the DES the 9-month results (follow-up DEB 39/45 [86.7%], DES 36/39 [92.3%]) are statistically not different at the 0.05 level for the primary endpoint of in-segment (0.37 ± 0.59 mm vs. 0.35 ± 0.63 mm) and in-stent (0.51 ± 0.61 mm vs. 0.53 ± 0.67 mm) late lumen loss, overall and cardiac deaths (2/45 [4.4%] and 3/45 [6.7%] vs. 0), target lesion revascularisation (3/45 [8.9%] vs. 4/39 [10.3%]), the total MACE rate (6/45 [13.3%] vs. 6/39 [15.4%]), and the event free survival after 10.2 ± 3.8 months (Kaplan-Meier analysis, p<0.80, log rank test). CONCLUSIONS: The clinical and angiographic outcome of the combination of the drug-eluting balloon SeQuent Please with a cobalt chromium stent compared to the drug eluting Taxus stent are similar.
Authors: Upendra Kaul; Martin Unverdorben; Ralf Degenhardt; Ashok Seth; Vinay K Bahl; Shirish M S Hiremath; Praveen Chandra; Ajit S Mullesari; P S Sandhu; Seshagiri Rao; Oommen George; Hanns Ackermann; Michael Boxberger Journal: Indian Heart J Date: 2013-09-13
Authors: Bruno Scheller; Dieter Fischer; Yvonne P Clever; Franz X Kleber; Ulrich Speck; Michael Böhm; Bodo Cremers Journal: Clin Res Cardiol Date: 2013-03-20 Impact factor: 5.460
Authors: Yvonne P Clever; Bodo Cremers; Wolfgang von Scheidt; Michael Böhm; Ulrich Speck; Bruno Scheller Journal: Clin Res Cardiol Date: 2013-09-26 Impact factor: 5.460
Authors: Franz X Kleber; Harald Rittger; Klaus Bonaventura; Uwe Zeymer; Jochen Wöhrle; Raban Jeger; Benny Levenson; Sven Möbius-Winkler; Leonhard Bruch; Dieter Fischer; Christian Hengstenberg; Tudor Pörner; Detlef Mathey; Bruno Scheller Journal: Clin Res Cardiol Date: 2013-08-28 Impact factor: 5.460
Authors: Georg M Fröhlich; Alexandra J Lansky; Dennis T Ko; Olga Archangelidi; Rodney De Palma; Adam Timmis; Pascal Meier Journal: BMC Med Date: 2013-05-08 Impact factor: 8.775