Literature DB >> 22027687

The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).

Joanna Wykrzykowska1, Patrick Serruys, Pawel Buszman, Axel Linke, Thomas Ischinger, Volker Klauss, Franz Eberli, Roberto Corti, William Wijns, Marie-Claude Morice, Carlo Di Mario, Robert-Jan Van Geuns, Gerrit-Anne Van Es, Peter Juni, Stephan Windecker.   

Abstract

AIMS: The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). METHODS AND
RESULTS: One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE.
CONCLUSIONS: The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22027687     DOI: 10.4244/EIJV7I7A125

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  10 in total

1.  Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent.

Authors:  Jinzhou Zhu; Huizhu Liu; Haipo Cui; Zhirong Tang; Chengli Song; Ruiyan Zhang
Journal:  J Mater Sci Mater Med       Date:  2017-02-14       Impact factor: 3.896

Review 2.  Advances in mammalian target of rapamycin kinase inhibitors: application to devices used in the treatment of coronary artery disease.

Authors:  Hiroyuki Jinnouchi; Liang Guo; Atsushi Sakamoto; Yu Sato; Anne Cornelissen; Rika Kawakami; Masayuki Mori; Sho Torii; Salome Kuntz; Emanuel Harari; Hiroyoshi Mori; Daniela Fuller; Neel Gadhoke; Raquel Fernandez; Ka Hyun Paek; Dipti Surve; Maria Romero; Frank D Kolodgie; Renu Virmani; Aloke V Finn
Journal:  Future Med Chem       Date:  2020-05-20       Impact factor: 3.808

Review 3.  Evolution of drug-eluting biomedical implants for sustained drug delivery.

Authors:  Juliana C Quarterman; Sean M Geary; Aliasger K Salem
Journal:  Eur J Pharm Biopharm       Date:  2020-12-16       Impact factor: 5.589

4.  Risk factors for long-term outcome of drug-eluting stenting in adults with early-onset coronary artery disease.

Authors:  Guipeng An; Zhongqi Du; Xiao Meng; Tao Guo; Guishuang Li; Yuguo Chen; Jifu Li; Fengshuang An; Yun Zhang; Wenjing Li; Cheng Zhang
Journal:  Int J Med Sci       Date:  2014-05-10       Impact factor: 3.738

5.  Preliminary Evaluation of Clinical and Angiographic Outcomes with Biodegradable Polymer Coated Sirolimus-Eluting Stent in De Novo Coronary Artery Disease: Results of the MANIPAL-FLEX Study.

Authors:  Ranjan Shetty; Jayesh Prajapati; Umesh Pai; Kiran Shetty
Journal:  Scientifica (Cairo)       Date:  2016-08-14

6.  Twelve-month clinical outcomes of sirolimus-eluting stent in coronary artery disease: An experience in real-world Indian patients.

Authors:  Srikanth Nathani; Asif Raheem; Harish Sanadhya; Prakash Chandra Purohit; Ramesh Patel; Praveen K Alane; Deepeshkumar Agarwal; Ramanand Sinha
Journal:  Anatol J Cardiol       Date:  2020-12       Impact factor: 1.596

7.  Risk factors for coronary drug-eluting stent thrombosis: influence of procedural, patient, lesion, and stent related factors and dual antiplatelet therapy.

Authors:  Krishnankutty Sudhir; James B Hermiller; Joanne M Ferguson; Charles A Simonton
Journal:  ISRN Cardiol       Date:  2013-06-23

8.  Stent thrombosis: incidence, predictors and new technologies.

Authors:  Gill Louise Buchanan; Sandeep Basavarajaiah; Alaide Chieffo
Journal:  Thrombosis       Date:  2012-03-11

9.  Real-world safety and effectiveness outcomes of a zotarolimus-eluting stent: final 3-year report of the RESOLUTE International study.

Authors:  Jorge A Belardi; Petr Widimský; Franz-Josef Neumann; Laura Mauri; Mariano Albertal
Journal:  J Interv Cardiol       Date:  2013-08-27       Impact factor: 2.279

10.  Randomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents: Nine months angiographic and 5-year clinical outcomes.

Authors:  Haijun Zhang; Xiangfei Wang; Wei Deng; Shenguo Wang; Junbo Ge; Egon Toft
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.