Literature DB >> 2202672

Tissue reaction involving an intraoral skin graft and CP titanium abutments: a clinical report.

D L Mitchell1, S A Synnott, J A VanDercreek.   

Abstract

Focal areas of gingival hyperplasia surrounding the transmucosal portions of titanium implants have been attributed to poor hygiene, lack of attached gingival tissues, and titanium allergy. Following mandibular vestibuloplasty and placement of a split-thickness skin graft, two of five patients developed persistent proliferation of the epithelial tissue surrounding endosseous CP titanium dental implants. In both circumstances, traditional gingivectomy procedures, chemotherapeutic agents, and aggressive oral hygiene measures failed to adequately control the hyperplastic response. Following replacement of the titanium abutments with custom-fabricated gold abutments, the epithelial condition appeared to return to normal.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2202672

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  [Allergic potential of titanium implants].

Authors:  A Schuh; P Thomas; W Kachler; J Göske; L Wagner; U Holzwarth; R Forst
Journal:  Orthopade       Date:  2005-04       Impact factor: 1.087

Review 2.  Hypersensitivity to titanium: a less explored area of research.

Authors:  Vasantha Vijayaraghavan; Ajay V Sabane; K Tejas
Journal:  J Indian Prosthodont Soc       Date:  2012-07-13

Review 3.  Allergic Reactions to Dental Materials-A Systematic Review.

Authors:  Meena Syed; Radhika Chopra; Vinod Sachdev
Journal:  J Clin Diagn Res       Date:  2015-10-01

4.  Allergy related to dental implant and its clinical significance.

Authors:  Tp Chaturvedi
Journal:  Clin Cosmet Investig Dent       Date:  2013-08-19

Review 5.  A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia.

Authors:  Reham B Osman; Michael V Swain
Journal:  Materials (Basel)       Date:  2015-03-05       Impact factor: 3.623

6.  Prevalence of Titanium Hypersensitivity in Patients with Titanium Implants: A Systematic Review and Meta-analysis.

Authors:  Rajsandeep Singh; Gurvanit Lehl; Arshad Bin Hussain; Tejal Nivrutti Abhang; Manisha Mangesh Kulkarni; Mohamed Fadul A Elagib; Rahul V C Tiwari
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

Review 7.  Titanium allergy: a literature review.

Authors:  Manish Goutam; Chandu Giriyapura; Sunil Kumar Mishra; Siddharth Gupta
Journal:  Indian J Dermatol       Date:  2014-11       Impact factor: 1.494

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.