Tamuro Hayama1, Soichiro Ishihara, Norihito Yamazaki, Takuya Akahane, Ryu Shimada, Atsushi Horiuchi, Hajime Shibuya, Hideki Yamada, Keijiro Nozawa, Keiji Matsuda, Toshiaki Watanabe.
Abstract
One rare complication of a ventriculoperitoneal (VP) shunt is perforation of the gastrointestinal tract by the catheter. We report a case in which the catheter severed spontaneously inside the peritoneal cavity, creating a communication between the intestinal tract and the peritoneal cavity. The patient was a 41-year-old man who presented with a VP shunt catheter protruding from the anus. Computed tomography showed that the VP shunt catheter, which had been put in place 25 years earlier, had severed spontaneously. The distal end had then perforated and entered the intestinal tract. The patient was hospitalized and emergency surgery was performed to repair the intestinal tract perforation caused by the end of the VP shunt catheter. Laparotomy revealed that the catheter had perforated the sigmoid colon. The VP shunt catheter was removed, and the perforation in the intestinal tract was closed by suturing. The patient was discharged on postoperative day 20.Entities:
Mesh:
Year: 2011 PMID: 22026307 DOI: 10.9738/1392.1
Source DB: PubMed Journal: Int Surg ISSN: 0020-8868