Literature DB >> 22024593

A novel enzymatic hydrogen peroxide biosensor based on Ag/C nanocables.

Chang-Jie Mao1, Xi-Bao Chen, He-Lin Niu, Ji-Ming Song, Sheng-Yi Zhang, Rong-Jing Cui.   

Abstract

A novel enzymatic hydrogen peroxide sensor was successfully fabricated based on the nanocomposites containing of Ag/C nanocables and gold nanoparticles (AuNPs). Ag/C nanocables have been synthesized by a hydrothermal method and then AuNPs were assembled on the surface of Ag/C nanocables. The nanocomposites were confirmed by X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy-dispersive X-ray spectrometry (EDS). The above nanocomposites have satisfactory chemical stability and excellent biocompatibility. Cyclic voltammetry (CV) was used to evaluate the electrochemical performance of the Ag/C/Au nanocomposites at glassy carbon electrode (GCE). The results indicated that the Ag/C/Au nanocomposites exhibited excellent electrocatalytic activity to the reduction of H(2)O(2). It offered a linear range of 6.7×10(-9) to 8.0×10(-6) M, with a detection limit of 2.2×10(-9) M. The apparent Michaelis-Menten constant of the biosensor was 51.7×10(-6) M. These results indicated that Ag/C/Au nanocomposites have potential for constructing of a variety of electrochemical biosensors.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22024593     DOI: 10.1016/j.bios.2011.10.001

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Immobilization of horseradish peroxidase on amino-functionalized carbon dots for the sensitive detection of hydrogen peroxide.

Authors:  Ya Su; Xuan Zhou; Yumei Long; Weifeng Li
Journal:  Mikrochim Acta       Date:  2018-01-15       Impact factor: 5.833

2.  A frogspawn-like Ag@C core-shell structure for an ultrasensitive label-free electrochemical immunosensing of carcinoembryonic antigen in blood plasma.

Authors:  Mengkui Ding; Ling Zha; Hui Wang; Jinyao Liu; Peiwu Chen; Yuefeng Zhao; Lan Jiang; Yuhao Li; Ruizhuo Ouyang; Yuqing Miao
Journal:  RSC Adv       Date:  2021-05-04       Impact factor: 4.036

3.  Facile fabrication of high-quality Ag/PS coaxial nanocables based on the mixed mode of soft/hard templates.

Authors:  Mimi Wan; Wenbo Zhao; Fang Peng; Qi Wang; Ping Xu; Chun Mao; Jian Shen
Journal:  Sci Rep       Date:  2016-08-01       Impact factor: 4.379

4.  Catalase-Based Modified Graphite Electrode for Hydrogen Peroxide Detection in Different Beverages.

Authors:  Giovanni Fusco; Paolo Bollella; Franco Mazzei; Gabriele Favero; Riccarda Antiochia; Cristina Tortolini
Journal:  J Anal Methods Chem       Date:  2016-12-18       Impact factor: 2.193

  4 in total