Literature DB >> 22023549

Cup-to-disc and arteriole-to-venule ratios in children aged 6-7 and 12-13 years.

Julie F McClelland1, Lisa O'Donoghue, Marta McIntyre, Kathryn J Saunders.   

Abstract

PURPOSE: Little data exist detailing the normal cup-to-disc (CD) ratios and arteriole-to-venule (A/V) ratios of school age children. In addition, controversy exists in the literature regarding associations between CD and A/V ratios and visual and biometric parameters. The present study investigates the success rates of obtaining useable optic disc images from the portable Nidek Handheld Non-Mydriatic Fundus Camera (NM-200D) from school-age children and describes the distribution of CD ratios and A/V ratios in children aged 6-7 years of age and 12-13 years of age. In addition, the present study explores associations between CD and A/V ratios and a range of visual function and biometric parameters in children.
METHODS: Fundus images were obtained from 195 6-7 year old children and 227 12-13 year old children participating in a wider study of visual function in childhood (Northern Ireland Childhood Errors of Refraction Study or NICER). ImageJ software was used to obtain CD and A/V ratios from the digital images. Visual function measures and biometric parameters were also available for all participants including; cycloplegic refractive error, vision, corneal curvature, axial length, height and weight.
RESULTS: One hundred and eighty fundus images (92.3%) from the 6-7 year olds and 194 images (85.5%) from the 12-13 year olds children were considered useable. Analysis (one way anova) demonstrated statistically significant differences between CD ratios and A/V ratios between the age groups. Participants aged 12-13 years had larger CD ratios and smaller A/V ratios (mean CD ratio 0.37 ± 0.09, mean A/V ratio 0.75 ± 0.10) than 6-7 year old participants (mean CD ratio 0.30 ± 0.09, mean A/V ratio 0.78 ± 0.12). No significant associations were noted between CD ratios and A/V ratio and any visual, ocular or biometric parameters.
CONCLUSIONS: The present study provides novel normative data on CD and A/V ratios in UK school age children for clinicians in practice. Ophthalmic & Physiological Optics
© 2011 The College of Optometrists.

Entities:  

Mesh:

Year:  2011        PMID: 22023549     DOI: 10.1111/j.1475-1313.2011.00878.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  5 in total

1.  Cup-to-disc and arteriole-to-venule ratios in preterm birth.

Authors:  J Kim; D Y Choi; K-A Park; S Y Oh
Journal:  Eye (Lond)       Date:  2015-06-19       Impact factor: 3.775

2.  The Distribution of Vertical Cup-to-Disc Ratio and its Determinants in the Iranian Adult Population.

Authors:  Hassan Hashemi; Reza Pakzad; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Abbasali Yekta; Akbar Fotouhi
Journal:  J Curr Ophthalmol       Date:  2020-07-04

3.  Characterization of the retinal vasculature in fundus photos using the PanOptic iExaminer system.

Authors:  Huiling Hu; Haicheng Wei; Mingxia Xiao; Liqiong Jiang; Huijuan Wang; Hong Jiang; Tatjana Rundek; Jianhua Wang
Journal:  Eye Vis (Lond)       Date:  2020-09-08

Review 4.  Portable hardware & software technologies for addressing ophthalmic health disparities: A systematic review.

Authors:  Margarita Labkovich; Megan Paul; Eliott Kim; Randal A Serafini; Shreyas Lakhtakia; Aly A Valliani; Andrew J Warburton; Aashay Patel; Davis Zhou; Bonnie Sklar; James Chelnis; Ebrahim Elahi
Journal:  Digit Health       Date:  2022-05-06

5.  Optic Nerve Head Development in Healthy Infants and Children Using Handheld Spectral-Domain Optical Coherence Tomography.

Authors:  Aarti Patel; Ravi Purohit; Helena Lee; Viral Sheth; Gail Maconachie; Eleni Papageorgiou; Rebecca J McLean; Irene Gottlob; Frank A Proudlock
Journal:  Ophthalmology       Date:  2016-08-09       Impact factor: 12.079

  5 in total