Literature DB >> 22021501

Gray-scale reversal for the detection of pulmonary nodules on a PACS workstation.

Diederick W De Boo1, Martin Uffmann, Shandra Bipat, Eelco F A Boorsma, Maeke J Scheerder, Michael Weber, Cornelia M Schaefer-Prokop.   

Abstract

OBJECTIVE: The purpose of this article is to evaluate the impact of gray-scale reversal on the detection of small pulmonary nodules in two-view chest radiography.
MATERIALS AND METHODS: One hundred twenty-eight patients (mean age, 62 years) who underwent CT and chest radiography within 6 weeks were retrospectively selected for this study. Seventy-three percent of patients showed variable degrees of radiographic findings of a "dirty lung." A total of 129 solid pulmonary nodules were present in 74 patients (nodule diameter range, 5-30 mm; mean diameter, 13 mm). The remaining 54 patients served as negative control subjects. Six readers with varying experience levels evaluated the images without and with the availability of gray-scale reversal in two separate reading sessions. Figure of merit (FOM), sensitivity per lesion, mean number of false-positive marks per image, and accuracy were calculated.
RESULTS: Five of the six readers showed a slight increase in sensitivity with the use of gray-scale reversal, but on average, the difference was not significant (48% vs 50%; p > 0.05). The mean number of false-positive marks per image also nonsignificantly increased from 0.20 to 0.23. The increases in both sensitivity and the mean number of false-positive marks per image translated into nonsignificant decreases in average FOM (0.79 vs 0.77) and accuracy (72% vs 71%). Data analysis of subgroups of nodules or different reader groups, depending on level of experience, did not reveal significant differences.
CONCLUSION: Using PACS display of digital chest radiographs, gray-scale reversal does not help the radiologists in detecting pulmonary nodules.

Entities:  

Mesh:

Year:  2011        PMID: 22021501     DOI: 10.2214/AJR.11.6625

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Gray scale inversion imaging (GSI) in Trauma and Orthopaedics.

Authors:  A Shah; K P Iyengar; R Botchu
Journal:  J Orthop       Date:  2022-02-16

2.  Comparison between conventional CT and grayscale inversion CT images in the assessment of the post-operative spinal orthopaedic implants.

Authors:  A Patel; S Haleem; R Rajakulasingam; S L James; A M Davies; R Botchu
Journal:  J Clin Orthop Trauma       Date:  2021-08-19

3.  Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population.

Authors:  Weixiang Sun; Jin Zhou; Xiaodong Qin; Leilei Xu; Xinxin Yuan; Yang Li; Yong Qiu; Zezhang Zhu
Journal:  BMC Musculoskelet Disord       Date:  2016-10-03       Impact factor: 2.362

4.  The impact of greyscale inversion for nodule detection in an anthropomorphic chest phantom: a free-response observer study.

Authors:  John D Thompson; Nigel B Thomas; David J Manning; Peter Hogg
Journal:  Br J Radiol       Date:  2016-06-08       Impact factor: 3.039

5.  The diagnostic value of grey-scale inversion technique in chest radiography.

Authors:  Roberta Eufrasia Ledda; Mario Silva; Nicole McMichael; Carlotta Sartorio; Cristina Branchi; Gianluca Milanese; Sundeep M Nayak; Nicola Sverzellati
Journal:  Radiol Med       Date:  2022-01-18       Impact factor: 3.469

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.