Literature DB >> 22020528

Complications of 1309 internal jugular vein cannulations with the anatomic landmarks technique in infants and children.

Shengfen Tu1, Xiaoyi Wang, Lin Bai, Hong Wang, Mao Ye, Yuan Shi, Shengde Wu, Xing Liu, Guanghui Wei.   

Abstract

PURPOSE: Report the procedural complications of internal jugular vein (IJV) catheter insertion in infants and children and discuss how to prevent them.
METHODS: An observational study was performed from January 2006 to August 2010; 1309 internal jugular vein cannulae were inserted in the operating room by either staff or resident anesthesiologists. Patient age, weight, sex, type of catheter (diameter, lumen number), number of attempts, and complications were recorded. The discussion is focused on how to prevent or reduce internal jugular vein line insertion related complications in infants and children.
RESULTS: 1309 IJV cannulae were inserted, 85.63% of catheters placed were successful after one to three attempts. Complications included 12 arrhythmias (0.91%), 25 arterial punctures (1.90%), 16 hematomas (1.22%), 17 device occlusions, breaks or malpositions (1.29%), 11 line-related infections (0.84%), four cases of thrombus (0.31%), two cardiopulmonary arrests (0.15%), two hemothoraces (0.15%), five pneumothoraces (0.38%), and one guidewire winding (0.07%). The complication rates of resident anesthesiologists were significantly higher compared to staff anesthesiologists for both common and rare complications (4.27% versus 2.21%; 0.68% versus 0.07%, respectively). In addition, residents' number of attempts were greater than staff anesthesiologists (1.84 and 1.38, respectively).
CONCLUSIONS: The IJV catheterization was feasible in infants and children. To reduce the risk of complications, the procedure should be performed or supervised by staff anesthesiologists; inserting the needle, guidewire, dilator, and the catheter too far should be avoided. It is now commonly accepted that all central venous cannulations should be performed under ultrasound guidance, especially in children.

Entities:  

Mesh:

Year:  2012        PMID: 22020528     DOI: 10.5301/jva.5000022

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  3 in total

Review 1.  Pediatric chest ultrasound: a practical approach.

Authors:  Mougnyan Cox; Michalle Soudack; Daniel J Podberesky; Monica Epelman
Journal:  Pediatr Radiol       Date:  2017-08-04

2.  Bilateral total parenteral nutrition pleural effusions in a 5-week-old male infant.

Authors:  Christopher Flannigan; Thomas Bourke; Karen Keown; Mark Terris
Journal:  BMJ Case Rep       Date:  2012-07-03

3.  The Right Internal Jugular at the Cricoid Cartilage Level May Represent the Optimal Central Vein Puncture Site in Pediatric Patients.

Authors:  Jun Xiong; Huijun Wang; Yun Zhu; Yafen Zhou; Yanan Pang; Liwei Zhang
Journal:  Front Pediatr       Date:  2022-02-22       Impact factor: 3.418

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.