Literature DB >> 22019878

Reducing image artefacts in concurrent TMS/fMRI by passive shimming.

Andreas Bungert1, Christopher D Chambers, Mark Phillips, C John Evans.   

Abstract

A significant problem in the concurrent application of transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) is the image artefact caused by the effect of the TMS-coil on the homogeneity of the static magnetic field (B0). The resulting field inhomogeneity can lead to spatial distortions and local signal loss in echo-planar (EP) images. Here we demonstrate that passive shimming using thin patches of austenitic stainless steel can reduce the effect of the TMS-coil on B0 by ~80%, thus essentially eliminating the associated artefact. Initially the effect of the TMS-coil on B0 was measured using the phase of gradient echo images. Consequently the ideal distribution for the steel was simulated using the magnetic properties of the steel and the effects of the TMS-coil. Finally we demonstrate the effect of two different implementations of the passive shim on a spherical phantom and in vivo.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22019878     DOI: 10.1016/j.neuroimage.2011.10.013

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  9 in total

1.  EPI distortion correction for concurrent human brain stimulation and imaging at 3T.

Authors:  Hyuntaek Oh; Jung Hwan Kim; Jeffrey M Yau
Journal:  J Neurosci Methods       Date:  2019-08-18       Impact factor: 2.390

2.  Static field influences on transcranial magnetic stimulation: considerations for TMS in the scanner environment.

Authors:  Jeffrey M Yau; Reza Jalinous; Gabriela L Cantarero; John E Desmond
Journal:  Brain Stimul       Date:  2014-02-20       Impact factor: 8.955

3.  Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom.

Authors:  Lucia I Navarro de Lara; Laleh Golestanirad; Sergey N Makarov; Jason P Stockmann; Lawrence L Wald; Aapo Nummenmaa
Journal:  Magn Reson Med       Date:  2020-01-23       Impact factor: 4.668

Review 4.  Precise Modulation Strategies for Transcranial Magnetic Stimulation: Advances and Future Directions.

Authors:  Gangliang Zhong; Zhengyi Yang; Tianzi Jiang
Journal:  Neurosci Bull       Date:  2021-10-05       Impact factor: 5.203

5.  On the definition of signal-to-noise ratio and contrast-to-noise ratio for FMRI data.

Authors:  Marijke Welvaert; Yves Rosseel
Journal:  PLoS One       Date:  2013-11-06       Impact factor: 3.240

6.  A novel coil array for combined TMS/fMRI experiments at 3 T.

Authors:  Lucia I Navarro de Lara; Christian Windischberger; Andre Kuehne; Michael Woletz; Jürgen Sieg; Sven Bestmann; Nikolaus Weiskopf; Bernhard Strasser; Ewald Moser; Elmar Laistler
Journal:  Magn Reson Med       Date:  2014-11-24       Impact factor: 4.668

7.  Simultaneous Transcranial Magnetic Stimulation and Functional Magnetic Resonance Imaging: Aspects of Technical Implementation.

Authors:  Elisabeth C Caparelli; Tianye Zhai; Yihong Yang
Journal:  Front Neurosci       Date:  2020-09-29       Impact factor: 4.677

Review 8.  TMS Does Not Increase BOLD Activity at the Site of Stimulation: A Review of All Concurrent TMS-fMRI Studies.

Authors:  Farshad Rafiei; Dobromir Rahnev
Journal:  eNeuro       Date:  2022-08-18

Review 9.  Combined neurostimulation and neuroimaging in cognitive neuroscience: past, present, and future.

Authors:  Sven Bestmann; Eva Feredoes
Journal:  Ann N Y Acad Sci       Date:  2013-04-30       Impact factor: 5.691

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.