Attila Mihalcz1, Imre Kassai, Attila Kardos, Csaba Foldesi, Dominic Theuns, Tamas Szili-Torok.
Abstract
BACKGROUND: Epicardial pacing lead implantation is the currently preferred surgical alternative for left ventricular (LV) lead placement. For endocardial LV pacing, we developed a fundamentally new surgical method. The trans-apical lead implantation is a minimally invasive technique that provides access to any LV segments. The aim of this prospective randomized study was to compare the outcome of patients undergoing either trans-apical endocardial or epicardial LV pacing.
METHODS: In group I, 11 end-stage heart failure (HF) patients (mean age 59.7 ± 7.9 years) underwent trans-apical LV lead implantation. Epicardial LV leads were implanted in 12 end-stage HF patients (group II; mean age 62.8 ± 7.3 years). Medical therapy was optimized in all patients. The following parameters were compared during an 18-month follow-up period: LV ejection fraction (LVEF), LV end-diastolic diameter (LVEDD), LV end-systolic diameter, and New York Heart Association (NYHA) functional class.
RESULTS: Nine out of 11 patients responded favorably to the treatment in group I (LVEF 39.7 ± 12.5 vs 26.0 ± 7.8%, P < 0.01; LVEDD 70.4 ± 13.6 mm vs 73.7 ± 10.5 mm, P = 0.002; NYHA class 2.2 ± 0.4 vs 3.5 ± 0.4, P < 0.01) and eight out of 12 in group II (LVEF 31.5 ± 11.5 vs 26.4 ± 8.9%, P = < 0.001; NYHA class 2.7 ± 0.4 vs 3.6 ± 0.4, P < 0.05). During the follow-up period, one patient died in group I and three in group II. There was one intraoperative LV lead dislocation in group I and one early postoperative dislocation in each group. None of the patients developed thromboembolic complications.
CONCLUSIONS: Our data suggest that trans-apical endocardial LV lead implantation is an alternative to epicardial LV pacing. ©2011, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
RCT Entities:
BACKGROUND: Epicardial pacing lead implantation is the currently preferred surgical alternative for left ventricular (LV) lead placement. For endocardial LV pacing, we developed a fundamentally new surgical method. The trans-apical lead implantation is a minimally invasive technique that provides access to any LV segments. The aim of this prospective randomized study was to compare the outcome of patients undergoing either trans-apical endocardial or epicardial LV pacing.
METHODS: In group I, 11 end-stage heart failure (HF) patients (mean age 59.7 ± 7.9 years) underwent trans-apical LV lead implantation. Epicardial LV leads were implanted in 12 end-stage HF patients (group II; mean age 62.8 ± 7.3 years). Medical therapy was optimized in all patients. The following parameters were compared during an 18-month follow-up period: LV ejection fraction (LVEF), LV end-diastolic diameter (LVEDD), LV end-systolic diameter, and New York Heart Association (NYHA) functional class.
RESULTS: Nine out of 11 patients responded favorably to the treatment in group I (LVEF 39.7 ± 12.5 vs 26.0 ± 7.8%, P < 0.01; LVEDD 70.4 ± 13.6 mm vs 73.7 ± 10.5 mm, P = 0.002; NYHA class 2.2 ± 0.4 vs 3.5 ± 0.4, P < 0.01) and eight out of 12 in group II (LVEF 31.5 ± 11.5 vs 26.4 ± 8.9%, P = < 0.001; NYHA class 2.7 ± 0.4 vs 3.6 ± 0.4, P < 0.05). During the follow-up period, one patient died in group I and three in group II. There was one intraoperative LV lead dislocation in group I and one early postoperative dislocation in each group. None of the patients developed thromboembolic complications.
CONCLUSIONS: Our data suggest that trans-apical endocardial LV lead implantation is an alternative to epicardial LV pacing. ©2011, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
Entities:
Mesh:
Year: 2011
PMID: 22017475 DOI: 10.1111/j.1540-8159.2011.03239.x
Source DB: PubMed Journal: Pacing Clin Electrophysiol ISSN: 0147-8389 Impact factor: 1.976