Literature DB >> 2201585

Ultrasonically guided histological and cytological fine needle biopsies of the pancreas. Reliability and reproducibility of diagnoses.

A Glenthøj1, M Sehested, S Torp-Pedersen.   

Abstract

In 100 consecutive patients ultrasonically guided histological and cytological fine needle biopsy specimens were obtained from pancreatic lesions using two different needles with an outer diameter of 0.6 mm. Specimens taken by both cytological and histological fine needle biopsy were examined blindly by two pathologists. When related to the final and reliable diagnosis obtained in 57 patients, the predictive value of a malignant diagnosis was 1.00 for both types of biopsy. The predictive value for a benign diagnosis was 0.25 for histological specimens for both examiners and 0.33 and 0.45 for the two evaluations of the cytological specimens. False benign diagnoses seemed to be related to both sampling error and difficulties in interpreting the biopsy specimens. The intraobserver and interobserver kappa values concerning reproducibility of diagnoses were higher for histological specimens (0.80 and 0.74) than for cytological specimens (0.70 and 0.61). Consistent malignant diagnoses, however, occurred more often with cytological specimens (51 cases) than with histological specimens (39 cases) (p less than 0.05) and consistent diagnoses of insufficient material were more common with histological specimens (18 cases v six cases). Cytological fine needle biopsy seems to be the method of choice if only one method is used and a 0.6 mm needle is used.

Entities:  

Mesh:

Year:  1990        PMID: 2201585      PMCID: PMC1378626          DOI: 10.1136/gut.31.8.930

Source DB:  PubMed          Journal:  Gut        ISSN: 0017-5749            Impact factor:   23.059


  25 in total

Review 1.  Percutaneous fine-needle aspiration biopsy of the pancreas.

Authors:  P M Bret; V Nicolet; M Labadie
Journal:  Diagn Cytopathol       Date:  1986-09       Impact factor: 1.582

2.  Percutaneous aspiration biopsy of the pancreas under ultrasonic guidance.

Authors:  L Bohár; A Bajtai; G Sarkadi; A Erös; J Gönczi
Journal:  Radiol Diagn (Berl)       Date:  1985

3.  Percutaneous fine needle aspiration biopsy of the pancreas. Cytodiagnosis of pancreatic carcinoma.

Authors:  L C Tao; C S Ho; M J McLoughlin; J McHattie
Journal:  Acta Cytol       Date:  1978 Jul-Aug       Impact factor: 2.319

4.  Percutaneous core biopsy of abdominal tumors using 22 gauge needles: further observations.

Authors:  J Wittenberg; P R Mueller; J T Ferrucci; J F Simeone; E vanSonnenberg; C C Neff; R A Palermo; R J Isler
Journal:  AJR Am J Roentgenol       Date:  1982-07       Impact factor: 3.959

5.  Histology from aspiration biopsy: Turner needle experience.

Authors:  R P Lieberman; G R Hafez; A B Crummy
Journal:  AJR Am J Roentgenol       Date:  1982-03       Impact factor: 3.959

6.  Ultrasound-guided percutaneous fine needle aspiration biopsy of abdominal and retroperitoneal masses. Accuracy of cytology in the diagnosis of malignancy, cytologic tumor typing and use of antibodies to intermediate filaments in selected cases.

Authors:  M Droese; M Altmannsberger; A Kehl; P G Lankisch; R Weiss; K Weber; M Osborn
Journal:  Acta Cytol       Date:  1984 Jul-Aug       Impact factor: 2.319

7.  Ultrasonically guided percutaneous fine needle biopsy of the pancreas.

Authors:  S Hancke; H H Holm; F Koch
Journal:  Surg Gynecol Obstet       Date:  1975-03

8.  Fine-needle aspiration cytodiagnosis: a simple and safe procedure for cancer of the pancreas.

Authors:  G Celle; V Savarino; E Biggi; C Mansi; P Ceppa; G R Cicio; V Arcuri
Journal:  Gastroenterol Clin Biol       Date:  1986 Aug-Sep

9.  Histological sampling with a 23 gauge modified Menghini needle.

Authors:  S Torp-Pedersen; N Juul; M Vyberg
Journal:  Br J Radiol       Date:  1984-02       Impact factor: 3.039

10.  Diagnostic reliability of histological and cytological fine needle biopsies from focal liver lesions.

Authors:  A Glenthøj; M Sehested; S Torp-Pedersen
Journal:  Histopathology       Date:  1989-10       Impact factor: 5.087

View more
  1 in total

1.  Comparison between echo-guided fine-needle aspiration cytology and microhistology in diagnosing pancreatic masses.

Authors:  L Solmi; R Muratori; P Bacchini; A Primerano; L Gandolfi
Journal:  Surg Endosc       Date:  1992 Sep-Oct       Impact factor: 4.584

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.