Literature DB >> 22013945

Clinical evaluation of immediate loading of electroeroded screw-retained titanium fixed prostheses supported by tilted implant: a multicenter retrospective study.

Alessandro Acocella1, Carlo Ercoli, Alessandro Geminiani, Changyong Feng, Mauro Billi, Gabriele Acocella, Domenico Giannini, Roberto Sacco.   

Abstract

STATEMENT OF PROBLEM: Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol.
PURPOSE: The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis.
MATERIALS AND METHODS: Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion.
RESULTS: Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%.
CONCLUSION: Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results.
© 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22013945     DOI: 10.1111/j.1708-8208.2011.00379.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  An alternative technique for fabrication of frameworks in an immediate loading implant fixed mandibular prosthesis.

Authors:  André Gustavo Paleari; Cristina Dupim Presoto; Juliano Alencar Vasconcelos; José Maurício Dos Santos Nunes Reis; Lígia Antunes Pereira Pinelli; Regina Helena Barbosa Tavares da Silva; Cristiane Campos Costa Quishida
Journal:  Case Rep Dent       Date:  2015-01-05

Review 2.  Horizontal augmentation techniques in the mandible: a systematic review.

Authors:  Ralf Smeets; Levi Matthies; Peter Windisch; Martin Gosau; Ronald Jung; Nadine Brodala; Martina Stefanini; Johannes Kleinheinz; Michael Payer; Anders Henningsen; Bilal Al-Nawas; Christian Knipfer
Journal:  Int J Implant Dent       Date:  2022-05-09

Review 3.  Revisiting the Complications of Orthodontic Miniscrew.

Authors:  Van Mai Truong; Soyeon Kim; Jaeheon Kim; Joo Won Lee; Young-Seok Park
Journal:  Biomed Res Int       Date:  2022-08-01       Impact factor: 3.246

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.