Literature DB >> 22012979

Evaluation of six commercial point-of-care tests for diagnosis of acute dengue infections: the need for combining NS1 antigen and IgM/IgG antibody detection to achieve acceptable levels of accuracy.

Stuart D Blacksell1, Richard G Jarman, Mark S Bailey, Ampai Tanganuchitcharnchai, Kemajittra Jenjaroen, Robert V Gibbons, Daniel H Paris, Ranjan Premaratna, H Janaka de Silva, David G Lalloo, Nicholas P J Day.   

Abstract

Six assays were evaluated in this study to determine their suitability for the diagnosis of acute dengue infection using samples from 259 Sri Lankan patients with acute fevers (99 confirmed dengue cases and 160 patients with other confirmed acute febrile illnesses): (i) the Merlin dengue fever IgG & IgM combo device (Merlin), (ii) the Standard Diagnostics Dengue Duo nonstructural 1 (NS1) antigen and IgG/IgM combo device (Standard Diagnostics, South Korea), (iii) the Biosynex Immunoquick dengue fever IgG and IgM (Biosynex, France) assay, (iv) the Bio-Rad NS1 antigen strip (Bio-Rad, France), (v) the Panbio Dengue Duo IgG/IgM Cassette (Inverness, Australia), and (vi) the Panbio dengue NS1 antigen strip (Inverness, Australia). The median number of days of fever prior to admission sample collection was 5 days (interquartile range, 3 to 7 days). Sensitivity and specificity of the NS1 antigen tests ranged from 49 to 59% and from 93 to 99%, respectively, and sensitivity and sensitivity of the IgM antibody test ranged from 71 to 80% and from 46 to 90%, respectively. Combining the NS1 antigen and IgM antibody results from the Standard Diagnostics Dengue Duo test gave the best compromise of sensitivity and specificity (93% and 89%, respectively) and provided the best sensitivity in patients presenting at different times after fever onset. The Merlin IgM/IgG antibody tests correctly classified 64% and 86% of the primary and secondary dengue infection cases, respectively, and the Standard Diagnostics IgM/IgG antibody tests correctly classified 71% and 83% of the primary and secondary dengue infection cases, respectively. This study provides strong evidence of the value of combining dengue antigen- and antibody-based test results in the rapid diagnostic test (RDT) format for the acute diagnosis of dengue.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22012979      PMCID: PMC3232692          DOI: 10.1128/CVI.05285-11

Source DB:  PubMed          Journal:  Clin Vaccine Immunol        ISSN: 1556-679X


  15 in total

1.  Rapid detection and typing of dengue viruses from clinical samples by using reverse transcriptase-polymerase chain reaction.

Authors:  R S Lanciotti; C H Calisher; D J Gubler; G J Chang; A V Vorndam
Journal:  J Clin Microbiol       Date:  1992-03       Impact factor: 5.948

2.  Techniques for hemagglutination and hemagglutination-inhibition with arthropod-borne viruses.

Authors:  D H CLARKE; J CASALS
Journal:  Am J Trop Med Hyg       Date:  1958-09       Impact factor: 2.345

Review 3.  A systematic review and meta-analysis of the diagnostic accuracy of rapid immunochromatographic assays for the detection of dengue virus IgM antibodies during acute infection.

Authors:  Stuart D Blacksell; Jenny A Doust; Paul N Newton; Sharon J Peacock; Nicholas P J Day; Arjen M Dondorp
Journal:  Trans R Soc Trop Med Hyg       Date:  2006-03-23       Impact factor: 2.184

4.  The burden of dengue infection.

Authors:  Scott B Halstead; Jose A Suaya; Donald S Shepard
Journal:  Lancet       Date:  2007-04-28       Impact factor: 79.321

5.  Enzyme-linked immunosorbent assay specific to Dengue virus type 1 nonstructural protein NS1 reveals circulation of the antigen in the blood during the acute phase of disease in patients experiencing primary or secondary infections.

Authors:  Sophie Alcon; Antoine Talarmin; Monique Debruyne; Andrew Falconar; Vincent Deubel; Marie Flamand
Journal:  J Clin Microbiol       Date:  2002-02       Impact factor: 5.948

6.  Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum.

Authors:  Philippe Dussart; Bhety Labeau; Gisèle Lagathu; Philippe Louis; Marcio R T Nunes; Sueli G Rodrigues; Cécile Storck-Herrmann; Raymond Cesaire; Jacques Morvan; Marie Flamand; Laurence Baril
Journal:  Clin Vaccine Immunol       Date:  2006-09-20

7.  An enzyme-linked immunosorbent assay to characterize dengue infections where dengue and Japanese encephalitis co-circulate.

Authors:  B L Innis; A Nisalak; S Nimmannitya; S Kusalerdchariya; V Chongswasdi; S Suntayakorn; P Puttisri; C H Hoke
Journal:  Am J Trop Med Hyg       Date:  1989-04       Impact factor: 2.345

8.  Adaptation of a microimmunofluorescence test to the study of human Rickettsia tsutsugamuskh antibody.

Authors:  D M Robinson; G Brown; E Gan; D L Huxsoll
Journal:  Am J Trop Med Hyg       Date:  1976-11       Impact factor: 2.345

9.  Dengue virus detection using whole blood for reverse transcriptase PCR and virus isolation.

Authors:  Chonticha Klungthong; Robert V Gibbons; Butsaya Thaisomboonsuk; Ananda Nisalak; Siripen Kalayanarooj; Vipa Thirawuth; Naowayubol Nutkumhang; Mammen P Mammen; Richard G Jarman
Journal:  J Clin Microbiol       Date:  2007-05-23       Impact factor: 5.948

10.  Evaluation of commercially available anti-dengue virus immunoglobulin M tests.

Authors:  Elizabeth A Hunsperger; Sutee Yoksan; Philippe Buchy; Vinh Chau Nguyen; Shamala D Sekaran; Delia A Enria; Jose L Pelegrino; Susana Vázquez; Harvey Artsob; Michael Drebot; Duane J Gubler; Scott B Halstead; María G Guzmán; Harold S Margolis; Carl-Michael Nathanson; Nidia R Rizzo Lic; Kovi E Bessoff; Srisakul Kliks; Rosanna W Peeling
Journal:  Emerg Infect Dis       Date:  2009-03       Impact factor: 6.883

View more
  65 in total

1.  Comparison of the mosquito inoculation technique and quantitative real time polymerase chain reaction to measure dengue virus concentration.

Authors:  Milly M Choy; Brett R Ellis; Esther M Ellis; Duane J Gubler
Journal:  Am J Trop Med Hyg       Date:  2013-09-09       Impact factor: 2.345

2.  NS1-based tests with diagnostic utility for confirming dengue infection: a meta-analysis.

Authors:  Hao Zhang; Wei Li; Junjie Wang; Hongjuan Peng; Xiaoyan Che; Xiaoguang Chen; Yuanping Zhou
Journal:  Int J Infect Dis       Date:  2014-06-28       Impact factor: 3.623

3.  Multicountry prospective clinical evaluation of two enzyme-linked immunosorbent assays and two rapid diagnostic tests for diagnosing dengue fever.

Authors:  Subhamoy Pal; Allison L Dauner; Andrea Valks; Brett M Forshey; Kanya C Long; Butsaya Thaisomboonsuk; Gloria Sierra; Victor Picos; Sara Talmage; Amy C Morrison; Eric S Halsey; Guillermo Comach; Chadwick Yasuda; Michael Loeffelholz; Richard G Jarman; Stefan Fernandez; Ung Sam An; Tadeusz J Kochel; Louis E Jasper; Shuenn-Jue L Wu
Journal:  J Clin Microbiol       Date:  2015-01-14       Impact factor: 5.948

4.  Bead-based multiplex detection of dengue biomarkers in a portable imaging device.

Authors:  Xilong Yuan; Srishti Garg; Kevin De Haan; Frederic A Fellouse; Anupriya Gopalsamy; Jan Tykvart; Sachdev S Sidhu; Manoj M Varma; Parama Pal; Edith M Hillan; James Jiahua Dou; J Stewart Aitchison
Journal:  Biomed Opt Express       Date:  2020-10-07       Impact factor: 3.732

5.  Comparison of a rapid immuno-chromatography assay with a standard ELISA for the detection of IgM and IgG antibodies against dengue viruses.

Authors:  Kalamathy Murugananthan; Pethirupillai A D Coonghe; Natkunam Ketheesan; Faseeha Noordeen
Journal:  Virusdisease       Date:  2018-04-17

6.  Comparison of seven commercial antigen and antibody enzyme-linked immunosorbent assays for detection of acute dengue infection.

Authors:  Stuart D Blacksell; Richard G Jarman; Robert V Gibbons; Ampai Tanganuchitcharnchai; Mammen P Mammen; Ananda Nisalak; Siripen Kalayanarooj; Mark S Bailey; Ranjan Premaratna; H Janaka de Silva; Nicholas P J Day; David G Lalloo
Journal:  Clin Vaccine Immunol       Date:  2012-03-21

7.  Two-Color Lateral Flow Assay for Multiplex Detection of Causative Agents Behind Acute Febrile Illnesses.

Authors:  Seoho Lee; Saurabh Mehta; David Erickson
Journal:  Anal Chem       Date:  2016-08-08       Impact factor: 6.986

Review 8.  Two cases of false-positive dengue non-structural protein 1 (NS1) antigen in patients with hematological malignancies and a review of the literature on the use of NS1 for the detection of Dengue infection.

Authors:  Shimin J Chung; Prabha U Krishnan; Yee Sin Leo
Journal:  Am J Trop Med Hyg       Date:  2014-11-10       Impact factor: 2.345

9.  Performance of the tourniquet test for diagnosing dengue in Peru.

Authors:  Eric S Halsey; Stalin Vilcarromero; Brett M Forshey; Claudio Rocha; Isabel Bazan; Steven T Stoddard; Tadeusz J Kochel; Martin Casapia; Thomas W Scott; Amy C Morrison
Journal:  Am J Trop Med Hyg       Date:  2013-05-28       Impact factor: 2.345

10.  Zika Virus-Associated Cerebellitis with Complete Clinical Recovery.

Authors:  Mónica R Pachar; Dimelza Araúz; Nathan D Gundacker; Marixcel Suárez; José Antonio Suárez; Brechla Moreno; Sandra López-Vergès; Ana B Araúz
Journal:  Am J Trop Med Hyg       Date:  2018-11       Impact factor: 2.345

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.