Literature DB >> 22011889

Effect of cement type and water storage time on the push-out bond strength of a glass fiber post.

Kátia Rodrigues Reis1, George Miguel Spyrides, Jonas Alves de Oliveira, Alexandre Abrão Jnoub, Kátia Regina Hostilio Cervantes Dias, Gerson Bonfantes.   

Abstract

This study investigated the effects of the cement type and the water storage time on the push-out bond strength of a glass fiber post. Glass fiber posts (Fibrekor, Jeneric Pentron) were luted to post spaces using a self-cured resin cement (C&B Cement [CB]), a glass ionomer cement (Ketac Cem [KC]) or a resin-modified glass ionomer cement (GC FujiCEM [FC]) according to the manufacturers' instructions. For each luting agent, the specimens were exposed to one of the following water storage times (n=5): 1 day (T1), 7 days (T7), 90 days (T90) and 180 days (T180). Push-out tests were performed after the storage times. Control specimens were not exposed to water storage, but subjected to the push-out test 10 min after post cementation. Data (in MPa) were analyzed by Kruskal-Wallis and Dunn`s test (α=0.05). Cement type and water storage time had a significant effect (p<0.05) on the push-out bond strength. CB showed significantly higher values of retention (p<0.05) than KC and FC, irrespective of the water storage time. Water storage increased significantly the push-out bond strength in T7 and T90, regardless of the cement type (p<0.05). The results showed that fiber posts luted to post spaces with the self-cured resin cement exhibited the best bonding performance throughout the 180-day water storage period. All cements exhibited a tendency to increase the bond strength after 7 and 90 days of water storage, decreasing thereafter.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22011889     DOI: 10.1590/s0103-64402011000500002

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  5 in total

1.  Influence of Different Post Luting Cements on the Fracture Strength of Endodontically Treated Teeth: An In Vitro Study.

Authors:  Abdulaziz Samran; Mohammed O Najjar; Ahlam Samran; Majed Al-Akhali; Sadeq A Al-Maweri; Mutlu Özcan
Journal:  Eur Endod J       Date:  2018-07-19

2.  Push-out bond strength of fiber posts to root dentin using glass ionomer and resin modified glass ionomer cements.

Authors:  Jefferson Ricardo Pereira; Ricardo Abreu da Rosa; Marcus Vinícius Reis Só; Daniele Afonso; Milton Carlos Kuga; Heitor Marques Honório; Accácio Lins do Valle; Hugo Alberto Vidotti
Journal:  J Appl Oral Sci       Date:  2014-07-04       Impact factor: 2.698

3.  Influence of the Cement Film Thickness on the Push-Out Bond Strength of Glass Fiber Posts Cemented in Human Root Canals.

Authors:  Natália Araújo Silva Prado; Reinaldo de Souza Ferreira; Marcos Henrique de Pinho Maurício; Sidnei Paciornik; Mauro Sayão de Miranda
Journal:  Int J Dent       Date:  2016-04-10

4.  Is the bonding of self-adhesive cement sensitive to root region and curing mode?

Authors:  Thaynara Faelly Boing; Giovana Mongruel Gomes; João Carlos Gomes; Alessandra Reis; Osnara Maria Mongruel Gomes
Journal:  J Appl Oral Sci       Date:  2017 Jan-Feb       Impact factor: 2.698

5.  Effect of time interval between core preparation and post cementation on pushout bond strength of glass fiber-reinforced posts.

Authors:  Mahsa Niakan; Ramin Mosharraf
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.