Literature DB >> 22011095

Surface changes of anodic oxidized orthodontic titanium miniscrew.

Sung-Hwan Choi1, Jung-Yul Cha, Uk-Hyon Joo, Chung-Ju Hwang.   

Abstract

OBJECTIVE: To evaluate the structural stability of anodic oxidation treatment of miniscrews during a self-drilling procedure and an initial loading period.
MATERIALS AND METHODS: Eight orthodontic miniscrews with a machined surface and an anodic oxidized surface were placed in the mandible of two beagle dogs. With all miniscrews, an orthodontic force was applied immediately after placement and was continued for 12 weeks. After beagle dogs were sacrificed, the miniscrews were carefully removed from decalcified bone fragments. Miniscrews were evaluated by comparing and quantitatively analyzing changes in surface roughness of unused and used miniscrews (machined surface vs anodic oxidized surface) utilizing both scanning electron microscopy (SEM) and atomic force microscopy (AFM).
RESULTS: SEM revealed that only a thread edge close to the tip of the used anodic oxidized miniscrew became smooth by smearing, compared with the unused anodic oxidized miniscrew. No definite changes were observed in the thread valleys of the two groups after placement. AFM measurements demonstrated that all surface roughness parameters of thread edges of the used anodic oxidized miniscrews were significantly reduced compared with the unused anodic oxidized miniscrew (P < .05). A middle thread edge of the used anodic miniscrew surface was rougher than the unused and used machined surface miniscrews (P < .05).
CONCLUSION: Anodic oxidized miniscrews had improved surface characteristics compared with machined surface miniscrews, even if the surface texture was changed by the self-drilling procedure and during the initial loading period.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22011095      PMCID: PMC8865829          DOI: 10.2319/071311-448.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  21 in total

1.  The friction and wear patterns of orthodontic brackets and archwires in the dry state.

Authors:  D J Michelberger; R L Eadie; M G Faulkner; K E Glover; N G Prasad; P W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2000-12       Impact factor: 2.650

2.  The effect of different screw-tightening techniques on the stress generated on an internal-connection implant superstructure.

Authors:  Jung-Han Choi; Young-Jun Lim; Chang-Whe Kim; Myung-Joo Kim
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Nov-Dec       Impact factor: 2.804

3.  Recommended placement torque when tightening an orthodontic mini-implant.

Authors:  Mitsuru Motoyoshi; Masayuki Hirabayashi; Miwa Uemura; Noriyoshi Shimizu
Journal:  Clin Oral Implants Res       Date:  2006-02       Impact factor: 5.977

4.  Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses.

Authors:  C Larsson; P Thomsen; B O Aronsson; M Rodahl; J Lausmaa; B Kasemo; L E Ericson
Journal:  Biomaterials       Date:  1996-03       Impact factor: 12.479

5.  True atomic resolution by atomic force microscopy through repulsive and attractive forces.

Authors:  F Ohnesorge; G Binnig
Journal:  Science       Date:  1993-06-04       Impact factor: 47.728

Review 6.  Biological applications of atomic force microscopy.

Authors:  R Lal; S A John
Journal:  Am J Physiol       Date:  1994-01

Review 7.  Role of material surfaces in regulating bone and cartilage cell response.

Authors:  B D Boyan; T W Hummert; D D Dean; Z Schwartz
Journal:  Biomaterials       Date:  1996-01       Impact factor: 12.479

8.  Analysis of seating and fracturing torque of bicortical screws.

Authors:  J A Ellis; D M Laskin
Journal:  J Oral Maxillofac Surg       Date:  1994-05       Impact factor: 1.895

9.  Bone response to alteration of surface topography and surface composition of sandblasted and acid etched (SLA) implants.

Authors:  Daniel Perrin; Serge Szmukler-Moncler; Casimir Echikou; Philippe Pointaire; Jean-Pierre Bernard
Journal:  Clin Oral Implants Res       Date:  2002-10       Impact factor: 5.977

Review 10.  Electrochemical surface modification of titanium in dentistry.

Authors:  Kyo-Han Kim; Narayanan Ramaswamy
Journal:  Dent Mater J       Date:  2009-01       Impact factor: 2.102

View more
  4 in total

1.  Behavior of osteoblasts on TI surface with two different coating designed for orthodontic devices.

Authors:  Leonardo Fleischmann; Adriano Crismani; Frank Falkensammer; Hans-Peter Bantleon; Xiaohui Rausch-Fan; Oleh Andrukhov
Journal:  J Mater Sci Mater Med       Date:  2015-01-11       Impact factor: 3.896

2.  Comparison between microporous and nanoporous orthodontic miniscrews : An experimental study in rabbits.

Authors:  Yueh-Tse Lee; Eric Jein-Wein Liou; Sinn-Wen Chen
Journal:  J Orofac Orthop       Date:  2022-05-20       Impact factor: 1.938

3.  Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles.

Authors:  Sung-Hwan Choi; Seong-Jin Kim; Kee-Joon Lee; Sang-Jin Sung; Youn-Sic Chun; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2016-07-25       Impact factor: 1.372

4.  Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews.

Authors:  Soon-Dong Yun; Sung-Hwan Choi; Jung-Yul Cha; Hyung-Seog Yu; Kwang-Mahn Kim; Jin Kim; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2017-05-26       Impact factor: 1.372

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.