Accuracy of impressions for internal-connection implant prostheses with various divergent angles.

Hee-Kon Jang1, Sungtae Kim, June-Sung Shim, Keun-Woo Lee, Hong-Seok Moon.   

Abstract

PURPOSE: The aim of this study was to determine the accuracies of implant-level impressions for internal-connection dental implants with various angles of divergence.
MATERIALS AND METHODS: Five groups were created according to the angles of divergence (0, 5, 10, 15, and 20 degrees) between two implant analogs in a master model. A master stone model for each group was fabricated. The divergent angle in each master model was verified with a profilometer. Study models (n = 10) from each master model were constructed through the implant-level impression technique. The divergent angle in each study model was verified with the profilometer. The splinted metal framework with passive fit was cast with base metal and cast-on abutments in each master model. The metal framework was tried in the study models and the fit of each framework was evaluated. One-way analysis of variance and the Tukey Honestly Significant Difference test were used for statistical analysis.
RESULTS: Statistically significant deformations of the impressions were found in the study models with divergently placed implant analogs. A larger divergence angle resulted in a larger gap between the framework and the implant analogs. The gap in the 20-degree divergence group differed significantly from that measured in the master model (P < .01).
CONCLUSIONS: Internal-connection implants were accurate when the divergence angle was less than 15 degrees. Inaccuracy of impressions increased as the divergence angle increased. The inaccuracy was significantly greater for the 20-degree-divergent implants than the other groups.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22010084

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Comparison of the accuracy of open-tray and snap-on impression techniques of implants with different angulations.

Authors:  Abbass Fallah Tafti; Mahnaz Hatami; Foroughsadat Razavi; Behnaz Ebadian
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

2.  Trueness of digital implant impressions based on implant angulation and scan body materials.

Authors:  Jae-Hyun Lee; Jae-Hwi Bae; Su Young Lee
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

3.  Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations.

Authors:  Chuang Bi; Xingyu Wang; Fangfang Tian; Zhe Qu; Jiaming Zhao
Journal:  J Adv Prosthodont       Date:  2022-08-29       Impact factor: 1.989

4.  Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study.

Authors:  G Parameshwari; B Chittaranjan; N Sudhir; C-K Anulekha-Avinash; M Taruna; M Ramureddy
Journal:  J Clin Exp Dent       Date:  2018-04-01

Review 5.  Assessment of intraoral scanning technology for multiple implant impressions - A systematic review and meta-analysis.

Authors:  Saloni Kachhara; Deepak Nallaswamy; Dhanraj M Ganapathy; Vinay Sivaswamy; Vaishnavi Rajaraman
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

6.  Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.

Authors:  Davide Farronato; Pietro Mario Pasini; Veronica Campana; Diego Lops; Lorenzo Azzi; Mattia Manfredini
Journal:  Odontology       Date:  2021-06-01       Impact factor: 2.634

  6 in total