Abstract

OBJECTIVE: To assess long-term clinical results of prosthetic disc nucleus (PDN) replacement for the treatment of lumbar disc herniation.
METHODS: Seventy-two patients with lumbar disc herniation were implanted with a single PDN device from March 2002 to December 2003. Fifty-eight (80.6%) patients attended clinical, functional, and radiographic follow-up examinations for more than 48 months. Independent analysis was performed by careful review of the interviews, operative reports, preoperative and postoperative radiographs, and computed tomography scans or magnetic resonance imaging (MRI).
RESULTS: After implantation, a significant proportion of patients experienced pain relief. Improvements were noted in pain intensity, walking distance, neurological weakness, Oswestry and Prolo scores, intervertebral disc height and lumbar mobility. Intervertebral disc height was not well maintained, compared with the preoperative height it decreased 18% (P < 0.001). Several complications were associated with the implantation of PDN, including transient low-back pain, implant dislocation, malposition of the implant, damage to the end plates and subsidence of implant.
CONCLUSION: The clinical data show that PDN is preferred and can effectively increase the range of lumbar motion in patients with lumbar disc herniation. However, this study only represents cases in our centre.
© 2009 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

Entities:  

Mesh:

Year:  2009        PMID: 22009782      PMCID: PMC6734642          DOI: 10.1111/j.1757-7861.2008.00010.x

Source DB:  PubMed          Journal:  Orthop Surg        ISSN: 1757-7853            Impact factor:   2.071


  2 in total

1.  A Radiographic Measurement of the Anterior Epidural Space at L4-5 Disc Level.

Authors:  Rui-Sheng Xu; Jie-Shi Wu; Hai-Dan Lu; Hao-Gang Zhu; Xia Li; Jian Dong; Feng-Lai Yuan
Journal:  Orthop Surg       Date:  2017-05-30       Impact factor: 2.071

2.  Biomechanical Evaluation of Spinal Column after Percutaneous Cement Discoplasty: A Finite Element Analysis.

Authors:  Shuang Li; Baoshan Xu; Yancheng Liu; Jingyu Zhang; Guijun Xu; Pengfei Shao; Xiaoye Li; Yongcheng Hu; Xinlong Ma
Journal:  Orthop Surg       Date:  2022-07-11       Impact factor: 2.279

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.