Literature DB >> 22005892

Long-term internal thoracic artery bypass graft patency and geometry assessed by multidetector computed tomography.

Mette Zacho1, Sune Damgaard, Nikolaj Thomas Lilleoer, Henning Kelbaek, Daniel Steinbrüchel, Michael Bachmann Nielsen, Klaus Fuglsang Kofoed.   

Abstract

The left internal thoracic artery (LITA) undergoes vascular remodelling when used for coronary artery bypass grafting. In this study we tested the hypothesis that the extent of the LITA remodelling late after coronary artery bypass grafting assessed by multidetector computed tomography is related to the severity of stenosis in the native coronary vessel. One hundred and forty-two patients who had undergone coronary artery bypass grafting including implantation of LITA as conduit to the left anterior descending artery were studied 5 years after surgery. Arterial graft patency and geometry was assessed with 64-slice multidetector computed tomography. Quantitative volumetric assessment of the LITA was performed to measure the average vessel lumen area (mm(2)/m(2)). The native coronary vessel subtended by the LITA was evaluated by multidetector computed tomography and defined as a high-grade stenosis patient group, when the diameter stenosis was >70% and an intermediate grade stenosis patient group when <70%. Among patients with intermediate-grade stenosis of the native vessel 11 out of 65 patients (17%) had a totally occluded LITA, as opposed to none among the 77 patients with a high-grade stenosis. In patients with intermediate-grade stenosis of the proximal native vessel, the LITA lumen area was 4.9 compared to 5.3 mm(2)/m(2) in patients with a high-grade stenosis of the proximal native vessel (P = 0.0043). Lumen area of the LITA when used as a conduit in patients with coronary artery disease seems to be inversely correlated with the severity of disease in the native coronary vessel proximal to the anastomosis. Volumetric vessel multidetector computed tomography appears to be useful for evaluation of coronary bypass remodelling.

Entities:  

Mesh:

Year:  2011        PMID: 22005892     DOI: 10.1007/s10554-011-9962-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  22 in total

1.  Lumen loss in the first year in saphenous vein grafts is predominantly a result of negative remodeling of the whole vessel rather than a result of changes in wall thickness.

Authors:  George T Lau; Lloyd J Ridley; Paul G Bannon; Louise A Wong; Joseph Trieu; David B Brieger; Harry C Lowe; Ben S Freedman; Leonard Kritharides
Journal:  Circulation       Date:  2006-07-04       Impact factor: 29.690

2.  Factors affecting internal mammary artery graft survival: how is competitive flow from a patent native coronary vessel a risk factor?

Authors:  S Pagni; J Storey; J Ballen; W Montgomery; N K Qaqish; S Etoch; P A Spence
Journal:  J Surg Res       Date:  1997-08       Impact factor: 2.192

3.  Three dimensional computed tomographic imaging in planning the surgical approach for redo cardiac surgery after coronary revascularization.

Authors:  Hrvoje Gasparovic; Frank J Rybicki; John Millstine; Daniel Unic; John G Byrne; Kent Yucel; Tomislav Mihaljevic
Journal:  Eur J Cardiothorac Surg       Date:  2005-08       Impact factor: 4.191

4.  Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years.

Authors:  G M Fitzgibbon; H P Kafka; A J Leach; W J Keon; G D Hooper; J R Burton
Journal:  J Am Coll Cardiol       Date:  1996-09       Impact factor: 24.094

5.  Changes in grafted and nongrafted coronary arteries following saphenous vein bypass grafting.

Authors:  B J Maurer; A Oberman; J H Holt; N T Kouchoukos; W B Jones; R O Russell; T J Reeves
Journal:  Circulation       Date:  1974-08       Impact factor: 29.690

6.  Improved noninvasive assessment of coronary artery bypass grafts with 64-slice computed tomographic angiography in an unselected patient population.

Authors:  Tanja S Meyer; Stefan Martinoff; Martin Hadamitzky; Albrecht Will; Adnan Kastrati; Albert Schömig; Jörg Hausleiter
Journal:  J Am Coll Cardiol       Date:  2007-02-20       Impact factor: 24.094

7.  Factors affecting saphenous vein graft patency: clinical and angiographic study in 1402 symptomatic patients operated on between 1977 and 1999.

Authors:  Pallav J Shah; Ian Gordon; John Fuller; Siven Seevanayagam; Alex Rosalion; James Tatoulis; Jai S Raman; Brian F Buxton
Journal:  J Thorac Cardiovasc Surg       Date:  2003-12       Impact factor: 5.209

8.  Does competitive flow reduce internal thoracic artery graft patency?

Authors:  Joseph F Sabik; Bruce W Lytle; Eugene H Blackstone; Mohammad Khan; Penny L Houghtaling; Delos M Cosgrove
Journal:  Ann Thorac Surg       Date:  2003-11       Impact factor: 4.330

9.  Volumetric evaluation of coronary plaque in patients presenting with acute myocardial infarction or stable angina pectoris-a multislice computerized tomography study.

Authors:  Sophia Hammer-Hansen; Klaus Fuglsang Kofoed; Henning Kelbaek; Thomas Kristensen; Jørgen Tobias Kühl; Jens Jakob Thune; Lars Køber
Journal:  Am Heart J       Date:  2008-12-23       Impact factor: 4.749

Review 10.  The "post-64" era of coronary CT angiography: understanding new technology from physical principles.

Authors:  Hansel J Otero; Michael L Steigner; Frank J Rybicki
Journal:  Radiol Clin North Am       Date:  2009-01       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.