Literature DB >> 22004059

Immediate loading in the maxillary arch: evidence-based guidelines to improve success rates: a review.

Sean Chung1, Anthony McCullagh, Tassos Irinakis.   

Abstract

The reliability of immediately loaded dental implants in the mandible has prompted many to investigate their application in the maxilla. Although the body of literature is growing, the long-term survivability of immediate loading in the maxilla is still pending. This review of literature investigates the status of immediate loading of dental implants in the maxilla to determine its predictability as a treatment option for partial and complete maxillary edentulism. Current terminology in the field is summarized first. Subsequently, the rationale and advantages of immediate loading in the maxilla are reviewed, and the relationships between immediate loading and osseointegration, primary stability, implant design, micromotion, immediate implant placement, and bone character are explored. The importance of a prosthodontically driven implant treatment plan emphasizing the role of splinting a high-precision and passively fitting implant restoration with reduced micromotion under function is summarized. The reliability and predictability of immediately loaded implants as a treatment option are proposed, and recommended guidelines for the successful delivery of immediately loaded implants in the maxilla are presented.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22004059     DOI: 10.1563/AAID-D-JOI-10-00058.1

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  5 in total

Review 1.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

2.  Digitally prefabricated versus conventionally fabricated implant-supported full-arch provisional prosthesis: a retrospective cohort study.

Authors:  Chaoqun Chen; Haiyan Lai; Huiyong Zhu; Xinhua Gu
Journal:  BMC Oral Health       Date:  2022-08-09       Impact factor: 3.747

3.  Measurement of primary and secondary stability of dental implants by resonance frequency analysis method in mandible.

Authors:  Mehran Shokri; Arash Daraeighadikolaei
Journal:  Int J Dent       Date:  2013-05-13

4.  Primary implant stability in augmented sinuslift-sites after completed bone regeneration: a randomized controlled clinical study comparing four subantrally inserted biomaterials.

Authors:  Angelo Troedhan; Izabela Schlichting; Andreas Kurrek; Marcel Wainwright
Journal:  Sci Rep       Date:  2014-07-30       Impact factor: 4.379

5.  Micromotion analysis of immediately loaded implants with Titanium and Cobalt-Chrome superstructures. 3D finite element analysis.

Authors:  Julio Tobar-Reyes; Luis Andueza-Castro; Antonio Jiménez-Silva; Roger Bustamante-Plaza; Juan Carvajal-Herrera
Journal:  Clin Exp Dent Res       Date:  2021-05-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.