Automatic extraction of 3D dynamic left ventricle model from 2D rotational angiocardiogram.

Mingqing Chen1, Yefeng Zheng, Kerstin Mueller, Christopher Rohkohl, Guenter Lauritsch, Jan Boese, Gareth Funka-Le, Joachim Hornegger, Dorin Comaniciu.   

Abstract

In this paper, we propose an automatic method to directly extract 3D dynamic left ventricle (LV) model from sparse 2D rotational angiocardiogram (each cardiac phase contains only five projections). The extracted dynamic model provides quantitative cardiac function for analysis. The overlay of the model onto 2D real-time fluoroscopic images provides valuable visual guidance during cardiac intervention. Though containing severe cardiac motion artifacts, an ungated CT reconstruction is used in our approach to extract a rough static LV model. The initialized LV model is projected onto each 2D projection image. The silhouette of the projected mesh is deformed to match the boundary of LV blood pool. The deformation vectors of the silhouette are back-projected to 3D space and used as anchor points for thin plate spline (TPS) interpolation of other mesh points. The proposed method is validated on 12 synthesized datasets. The extracted 3D LV meshes match the ground truth quite well with a mean point-to-mesh error of 0.51 +/- 0.11 mm. The preliminary experiments on two real datasets (included a patient and a pig) show promising results too.

Entities:  

Mesh:

Year:  2011        PMID: 22003733     DOI: 10.1007/978-3-642-23626-6_58

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  3 in total

1.  Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data.

Authors:  Kerstin Müller; Chris Schwemmer; Joachim Hornegger; Yefeng Zheng; Yang Wang; Günter Lauritsch; Christopher Rohkohl; Andreas K Maier; Carl Schultz; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

2.  Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT.

Authors:  K Müller; A K Maier; C Schwemmer; G Lauritsch; S De Buck; J-Y Wielandts; J Hornegger; R Fahrig
Journal:  Phys Med Biol       Date:  2014-05-20       Impact factor: 3.609

3.  Interventional heart wall motion analysis with cardiac C-arm CT systems.

Authors:  Kerstin Müller; Andreas K Maier; Yefeng Zheng; Yang Wang; Günter Lauritsch; Chris Schwemmer; Christopher Rohkohl; Joachim Hornegger; Rebecca Fahrig
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.