Literature DB >> 22001239

Interface quality of endothelial keratoplasty buttons obtained with optimised femtosecond laser settings.

Antoine Rousseau1, Abdelkader Bensalem, Virginie Garnier, Michèle Savoldelli, Jean-Jacques Saragoussi, Gilles Renard, Jean-Louis Bourges.   

Abstract

AIM: To optimise interfaces of endothelial buttons created with femtosecond (FS) lasers.
SETTING: Department of Ophthalmology, Hôtel-Dieu Hospital, Paris, France.
METHODS: Forty-two corneas were divided into five groups of various cutting patterns and a control group of 100 μm laser in situ keratomileusis flap creation. A single path full lamellar cut (500 μm) was applied to groups 1 and 2. The same full lamellar cut was applied twice to groups 3 and 4. Two successive lamellar cuts were performed in group 5 (350 and 150 μm). 60 kHz and 150 kHz were used respectively in groups 1, 3, 5, 6 and 2, 4. In each group, different laser settings were tested to obtain the best interface quality while delivering minimal energy to the stroma. The quality of stromal interfaces from created endothelial lenticules was observed using a scanning electron microscope.
RESULTS: Stromal adherences persisted after both the single- and double-path procedure, creating central irregularities on the endothelial lenticule. Among all groups and settings tested, the double-layer pattern (group 5) with FS full lamellar cut parameters set for diameter (mm), depth (μm), energy (μJ) and spot size/step (μm) respectively on 9.0 mm, 350 μm, 2.1 μJ, 4:4 μm and 8.3 mm, 150 μm, 0.9 μJ, 4:4 μm created the smoothest interfaces with the best reproducibility.
CONCLUSIONS: Buttons for endothelial keratoplasty can be created with FS laser with a stromal interface quality comparable with that of refractive surgery.

Entities:  

Mesh:

Year:  2011        PMID: 22001239     DOI: 10.1136/bjophthalmol-2011-300463

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  4 in total

1.  Double-pass microkeratome technique for ultra-thin graft preparation in Descemet's stripping automated endothelial keratoplasty.

Authors:  Maylon Hsu; Walter L Hereth; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2012-03-16

2.  Comparative study of corneal endothelial cell damage after femtosecond laser assisted deep stromal dissection.

Authors:  Ting Liu; Jingjing Zhang; Dapeng Sun; Wenjie Sui; Yangyang Zhang; Dongfang Li; Zhaoli Chen; Hua Gao
Journal:  Biomed Res Int       Date:  2014-07-10       Impact factor: 3.411

3.  Posterior lamellar graft preparation: a prospective review from an eye bank on current and future aspects.

Authors:  Mohit Parekh; Gianni Salvalaio; Alessandro Ruzza; Davide Camposampiero; Carlo Griffoni; Alfonso Zampini; Diego Ponzin; Stefano Ferrari
Journal:  J Ophthalmol       Date:  2013-05-30       Impact factor: 1.909

4.  Surface quality and endothelial cell viability after femtosecond laser-assisted donor lenticule preparation for endothelial keratoplasty - An in-vitro study.

Authors:  Jeewan S Titiyal; M J Aravind; Manpreet Kaur; Tapas C Nag; Namrata Sharma; Tushar Agarwal; Rajesh Sinha
Journal:  Indian J Ophthalmol       Date:  2020-11       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.