Infrared spectroscopic analysis of human interstitial fluid in vitro and in vivo using FT-IR spectroscopy and pulsed quantum cascade lasers (QCL): Establishing a new approach to non invasive glucose measurement.

Miguel Pleitez1, Hermann von Lilienfeld-Toal, Werner Mäntele.   

Abstract

Interstitial fluid, i.e. the liquid present in the outermost layer of living cells of the skin between the Stratum corneum and the Stratum spinosum, was analyzed by Fourier transform infrared spectroscopy and by infrared spectroscopy using pulsed quantum cascade infrared lasers with photoacoustic detection. IR spectra of simulated interstitial fluid samples and of real samples from volunteers in the 850-1800cm(-1) range revealed that the major components of interstitial fluid are albumin and glucose within the physiological range, with only traces of sodium lactate if at all. The IR absorbance of glucose in interstitial fluid in vivo was probed in healthy volunteers using a setup with quantum cascade lasers and photoacoustic detection previously described. A variation of blood glucose between approx. 80mg/dl and 250mg/dl in the volunteers was obtained using the standard oral glucose tolerance test (OGT). At two IR wavelengths, 1054cm(-1) and 1084cm(-1), a reasonable correlation between the photoacoustic signal from the skin and the blood glucose value as determined by conventional glucose test sticks using blood from the finger tip was obtained. The infrared photoacoustic glucose signal (PAGS) may serve as the key for a non-invasive glucose measurement, since the glucose content in interstitial fluid closely follows blood glucose in the time course and in the level (a delay of some minutes and a level of approx. 80-90% of the glucose level in blood). Interstitial fluid is present in skin layers at a depth of only 15-50μm and is thus within the reach of mid-IR energy in an absorbance measurement. A non-invasive glucose measurement for diabetes patients based on mid-infrared quantum cascade lasers and photoacoustic detection could replace the conventional measurement using enzymatic test stripes and a drop of blood from the finger tip, thus reducing pain and being a cost-efficient alternative for millions of diabetes patients.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22000639     DOI: 10.1016/j.saa.2011.09.007

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  13 in total

1.  In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor.

Authors:  Songlin Yu; Dachao Li; Hao Chong; Changyue Sun; Haixia Yu; Kexin Xu
Journal:  Biomed Opt Express       Date:  2013-12-17       Impact factor: 3.732

Review 2.  Current state of the art for enhancing urine biomarker discovery.

Authors:  Michael Harpole; Justin Davis; Virginia Espina
Journal:  Expert Rev Proteomics       Date:  2016-06       Impact factor: 3.940

3.  Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring.

Authors:  Yihao Chen; Siyuan Lu; Shasha Zhang; Yan Li; Zhe Qu; Ying Chen; Bingwei Lu; Xinyan Wang; Xue Feng
Journal:  Sci Adv       Date:  2017-12-20       Impact factor: 14.136

4.  Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics.

Authors:  Jonas Kottmann; Julien M Rey; Markus W Sigrist
Journal:  Sensors (Basel)       Date:  2016-10-10       Impact factor: 3.576

5.  Covalent modification of human serum albumin by the natural sesquiterpene lactone parthenolide.

Authors:  Michael Plöger; Jandirk Sendker; Klaus Langer; Thomas J Schmidt
Journal:  Molecules       Date:  2015-04-09       Impact factor: 4.411

6.  Parametric standing wave generation of a shallow reflection plane in a nonrigid sample for use in a noninvasive blood glucose monitor.

Authors:  Tomoya Kitazaki; Natsumi Kawashima; Naoyuki Yamamoto; Hiroyuki Nomura; Hanyue Kang; Akira Nishiyama; Kenji Wada; Ichiro Ishimaru
Journal:  J Biomed Opt       Date:  2019-03       Impact factor: 3.170

7.  Evaluation of a Novel Noninvasive Blood Glucose Monitor Based on Mid-Infrared Quantum Cascade Laser Technology and Photothermal Detection.

Authors:  Thorsten Lubinski; Bartosz Plotka; Sergius Janik; Luca Canini; Werner Mäntele
Journal:  J Diabetes Sci Technol       Date:  2020-07-05

8.  Glucose sensing in human epidermis using mid-infrared photoacoustic detection.

Authors:  Jonas Kottmann; Julien M Rey; Joachim Luginbühl; Ernst Reichmann; Markus W Sigrist
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

9.  Mid-infrared fiber-coupled photoacoustic sensor for biomedical applications.

Authors:  Jonas Kottmann; Urs Grob; Julien M Rey; Markus W Sigrist
Journal:  Sensors (Basel)       Date:  2013-01-02       Impact factor: 3.576

10.  Microneedle-based skin patch for blood-free rapid diagnostic testing.

Authors:  Xue Jiang; Peter B Lillehoj
Journal:  Microsyst Nanoeng       Date:  2020-11-02       Impact factor: 7.127

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.