Literature DB >> 22000575

Disappointing short-term results with the DePuy ASR XL metal-on-metal total hip arthroplasty.

Nicholas M Bernthal1, Paul C Celestre, Alexandra I Stavrakis, John C Ludington, Daniel A Oakes.   

Abstract

Outcomes of ultralarge-diameter femoral heads used in metal-on-metal (MOM) total hip arthroplasty (THA) are relatively unknown. This study reports on early failures of the ASR XL (Depuy, Warsaw, Ind) and assesses whether a correlation with cup positioning exists. A retrospective review of 70 consecutive MOM THAs with ultralarge-diameter femoral head and monoblock acetabular component was conducted. Minimum follow-up was 24 months. Of 70 THAs, 12 (17.1%) required revision within 3 years for pain (7), loosening (3), and squeaking (2). Three additional THAs noted squeaking, 2 noted grinding, and 3 additional hips had persistent pain. In total, 20 (28.6%) of 70 demonstrated implant dysfunction. Acetabular components for all symptomatic hips were in acceptable range of cup abduction and anteversion. The failures noted with this design do not correlate to cup placement. The high rate of implant dysfunction at early follow-up suggests serious concerns with the concept of MOM THA with an ultralarge-diameter femoral head paired with a monoblock acetabular cup. Copyright Â
© 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22000575     DOI: 10.1016/j.arth.2011.08.022

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.

Authors:  Adolph V Lombardi; Keith R Berend; Michael J Morris; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2014-11-04       Impact factor: 4.176

2.  Revisions of monoblock metal-on-metal THAs have high early complication rates.

Authors:  Louis S Stryker; Susan M Odum; Thomas K Fehring; Bryan D Springer
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

3.  Medium term review of the ASR implant system: A single surgeon series.

Authors:  M Curtin; E Murphy; C Bryan; D Jadaan; M Jadaan; D Bergin; C G Murphy; W Curtin
Journal:  J Orthop       Date:  2017-02-03

4.  Letter to the Editor: Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions.

Authors:  David J Langton
Journal:  Clin Orthop Relat Res       Date:  2018-11       Impact factor: 4.176

5.  The withdrawn ASR™ THA and hip resurfacing systems: how have our patients fared over 1 to 6 years?

Authors:  Kevin T Hug; Tyler S Watters; Thomas P Vail; Michael P Bolognesi
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

6.  Innovation in orthopaedic surgery as it relates to evidence-based practice.

Authors:  M Hofbauer; B Muller; C D Murawski; J Karlsson; Freddie H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03       Impact factor: 4.342

7.  Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions.

Authors:  Sang-Hyun Park; Zhen Lu; Robert S Hastings; Patricia A Campbell; Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

8.  Metal-on-metal total hip arthroplasty: is there still a role in 2016?

Authors:  Edward J Silverman; Blair Ashley; Neil P Sheth
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

9.  Cumulative revision rate is higher in metal-on-metal THA than metal-on-polyethylene THA: analysis of survival in a community registry.

Authors:  Der-Chen T Huang; Penny Tatman; Susan Mehle; Terence J Gioe
Journal:  Clin Orthop Relat Res       Date:  2013-02-08       Impact factor: 4.176

10.  ISHKS joint registry: A preliminary report.

Authors:  Jawahir A Pachore; Shrinand V Vaidya; Chandrasekhar J Thakkar; Haresh Kumar P Bhalodia; Hemant M Wakankar
Journal:  Indian J Orthop       Date:  2013-09       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.