Literature DB >> 22000574

Follow-up of a modular rotating hinge knee system in salvage revision total knee arthroplasty.

Daniel R P Neumann1, Thomas Hofstaedter, Ulrich Dorn.   

Abstract

We evaluated the clinical and radiographic outcomes of salvage knee revisions using a modern-generation, modular, rotating hinge total knee prosthesis in 24 cases with a minimum follow-up of 36 months (mean, 56 months). Indications for revision included aseptic loosening, combined with bone loss and gross collateral ligament instability in all cases. Patients were evaluated clinically and radiographically (Knee Society scores). Knee Society scores improved from 25 preoperatively to 91 postoperatively, and function scores improved from 35 to 85. No loosening of implants was observed. Nonprogressive radiolucent lines were identified around 2 tibial components. One patient required a revision due to patellofemoral subluxation.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22000574     DOI: 10.1016/j.arth.2011.08.015

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  KNEE ARTHROPLASTY REVISION WITH A CONSTRAINED IMPLANT USING HINGE AND ROTATING TIBIAL BASIS.

Authors:  Fabio Jansen Angelini; Camilo Partezani Helito; Bruno Azevedo Veronesi; Tales Mollica Guimarães; José Ricardo Pécora; Marco Kawamura Demange
Journal:  Acta Ortop Bras       Date:  2016 Jan-Feb       Impact factor: 0.513

Review 2.  Rotating hinge prosthesis for complex revision total knee arthroplasty: A review of the literature.

Authors:  Shalen Kouk; Parthiv A Rathod; Aditya V Maheshwari; Ajit J Deshmukh
Journal:  J Clin Orthop Trauma       Date:  2017-12-05

3.  Constraint choice in revision knee arthroplasty: study protocol of a randomised controlled trial assessing the effect of level of constraint on postoperative outcome.

Authors:  Hagen Hommel; Kai Wilke; Daniel Kunze; Peggy Hommel; Peter Fennema
Journal:  BMJ Open       Date:  2017-03-27       Impact factor: 2.692

4.  Knee arthroplasty with rotating-hinge implant: an option for complex primary cases and revisions.

Authors:  Camilo Partezani Helito; Pedro Nogueira Giglio; Camila Maftoum Cavalheiro; Riccardo Gomes Gobbi; Marco Kawamura Demange; Gilberto Luis Camanho
Journal:  Rev Bras Ortop       Date:  2018-02-21

5.  Implant survivorship, functional outcomes and complications with the use of rotating hinge knee implants: a systematic review.

Authors:  Joshua Xu; Lennart von Fritsch; Shiraz A Sabah; Andrew J Price; Abtin Alvand
Journal:  Knee Surg Relat Res       Date:  2022-03-04

6.  Differences in gait kinetics and kinematics between patients with rotating hinge knee and cruciate-retaining prostheses: a cross-sectional study.

Authors:  Takehiro Ohmi; Takumi Yamada; Sadaya Misaki; Tomohiro Tazawa; Ryota Shimamura; Junpei Kato; Kazutaka Sugimoto
Journal:  J Phys Ther Sci       Date:  2022-09-01

7.  Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision.

Authors:  Turgay Efe; Philip P Roessler; Thomas J Heyse; Carsten Hauk; Caroline Pahrmann; Alan Getgood; Jan Schmitt
Journal:  Orthop Rev (Pavia)       Date:  2012-12-11

Review 8.  Total knee arthroplasty using hinge joints: Indications and results.

Authors:  E Carlos Rodríguez-Merchán
Journal:  EFORT Open Rev       Date:  2019-04-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.