Literature DB >> 21997287

A reliable transmission protocol for ZigBee-based wireless patient monitoring.

Shyr-Kuen Chen1, Tsair Kao, Chia-Tai Chan, Chih-Ning Huang, Chih-Yen Chiang, Chin-Yu Lai, Tse-Hua Tung, Pi-Chung Wang.   

Abstract

Patient monitoring systems are gaining their importance as the fast-growing global elderly population increases demands for caretaking. These systems use wireless technologies to transmit vital signs for medical evaluation. In a multihop ZigBee network, the existing systems usually use broadcast or multicast schemes to increase the reliability of signals transmission; however, both the schemes lead to significantly higher network traffic and end-to-end transmission delay. In this paper, we present a reliable transmission protocol based on anycast routing for wireless patient monitoring. Our scheme automatically selects the closest data receiver in an anycast group as a destination to reduce the transmission latency as well as the control overhead. The new protocol also shortens the latency of path recovery by initiating route recovery from the intermediate routers of the original path. On the basis of a reliable transmission scheme, we implement a ZigBee device for fall monitoring, which integrates fall detection, indoor positioning, and ECG monitoring. When the triaxial accelerometer of the device detects a fall, the current position of the patient is transmitted to an emergency center through a ZigBee network. In order to clarify the situation of the fallen patient, 4-s ECG signals are also transmitted. Our transmission scheme ensures the successful transmission of these critical messages. The experimental results show that our scheme is fast and reliable. We also demonstrate that our devices can seamlessly integrate with the next generation technology of wireless wide area network, worldwide interoperability for microwave access, to achieve real-time patient monitoring.

Entities:  

Mesh:

Year:  2011        PMID: 21997287     DOI: 10.1109/TITB.2011.2171704

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  7 in total

1.  Wireless electrocardiogram transmission in ISM band: an approach towards telecardiology.

Authors:  R Gupta; M Mitra
Journal:  J Med Syst       Date:  2014-08-02       Impact factor: 4.460

2.  The virtual toxicology service: wearable head-mounted devices for medical toxicology.

Authors:  Peter R Chai; Roger Y Wu; Megan L Ranney; Paul S Porter; Kavita M Babu; Edward W Boyer
Journal:  J Med Toxicol       Date:  2014-12

3.  A Fatigue Measuring Protocol for Wireless Body Area Sensor Networks.

Authors:  Sana Akram; Nadeem Javaid; Ashfaq Ahmad; Zahoor Ali Khan; Muhammad Imran; Mohsen Guizani; Amir Hayat; Manzoor Ilahi
Journal:  J Med Syst       Date:  2015-10-21       Impact factor: 4.460

4.  Towards Reliable and Energy-Efficient Incremental Cooperative Communication for Wireless Body Area Networks.

Authors:  Sidrah Yousaf; Nadeem Javaid; Umar Qasim; Nabil Alrajeh; Zahoor Ali Khan; Mansoor Ahmed
Journal:  Sensors (Basel)       Date:  2016-02-24       Impact factor: 3.576

5.  Patient Posture Monitoring System Based on Flexible Sensors.

Authors:  Youngsu Cha; Kihyuk Nam; Doik Kim
Journal:  Sensors (Basel)       Date:  2017-03-13       Impact factor: 3.576

6.  Energy-Efficient Elderly Fall Detection System Based on Power Reduction and Wireless Power Transfer.

Authors:  Sadik Kamel Gharghan; Saif Saad Fakhrulddin; Ali Al-Naji; Javaan Chahl
Journal:  Sensors (Basel)       Date:  2019-10-14       Impact factor: 3.576

7.  A ZigBee-based location-aware fall detection system for improving elderly telecare.

Authors:  Chih-Ning Huang; Chia-Tai Chan
Journal:  Int J Environ Res Public Health       Date:  2014-04-16       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.