Literature DB >> 21996445

Development of a discriminatory biocompatibility testing model for non-precious dental casting alloys.

Emma Louise McGinley1, Garry J P Fleming, Gary P Moran.   

Abstract

OBJECTIVES: To develop an enhanced, reproducible and discriminatory biocompatibility testing model for non-precious dental casting alloys, prepared to a clinically relevant surface finishing condition, using TR146 oral keratinocyte cells.
METHODS: Comparative biocompatibility was determined following direct and indirect exposure of TR146 cells to two nickel-chromium (Ni-Cr) and a cobalt-chromium (Co-Cr) alloy-discs. The surface roughness of the discs was determined using a contact stylus profilometer and the elemental ion release by inductively coupled plasma mass spectrometry (ICP-MS). Subsequent biocompatibility analysis included cell morphology, cell density measurements with Trypan blue exclusion assay, inflammatory cytokine expression with ELISAs, cellular metabolic activity using XTT and cellular toxicity using lactate dehydrogenase (LDH) release assay.
RESULTS: TR146 cell morphology was altered following direct and indirect exposure to the Ni-Cr alloys but not the Co-Cr alloy. Significant reductions (all P<0.001) in viable cell density measurements, cellular metabolic activity, significant increases inflammatory cytokine expression and cellular toxicity were observed when TR146 cells were exposed to the Ni-Cr alloys. Significant decreases in cell density measurements, cellular metabolic activity, significant increases inflammatory cytokine expression and cellular toxicity for the Ni-Cr d.Sign(®)15 alloy compared with d.Sign(®)10 alloy were identifiable (all P<0.001). Cellular toxicity was attributed to nickel ion release levels in solution detected by ICP-MS analysis. DISCUSSION: Nickel ions from the Ni-Cr alloys permeated the epithelial cells and activated a proinflammatory response, namely IL-1a, IL-8 and PGE2 expression. Further evidence of nickel ioninduced cell death was supported by the decreased biocompatibility of the highest nickel ion releasing alloy (d.Sign(®)15 compared with d.Sign(®)10) and the increased biocompatibility of the Co-Cr (d.Sign(®)30) alloy where nickel ions were absent.
Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21996445     DOI: 10.1016/j.dental.2011.09.013

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  5 in total

1.  In vitro biocompatibility assessment of Ti40Cu38Zr10Pd12 bulk metallic glass.

Authors:  A Blanquer; E Pellicer; A Hynowska; L Barrios; E Ibáñez; M D Baró; J Sort; C Nogués
Journal:  J Mater Sci Mater Med       Date:  2014-01       Impact factor: 3.896

2.  The concentrations of IL-8 and IL-6 in gingival crevicular fluid during nickel-chromium alloy porcelain crown restoration.

Authors:  Lufeng Yu; JianSheng Su; DeRong Zou; Zana Mariano
Journal:  J Mater Sci Mater Med       Date:  2013-04-07       Impact factor: 3.896

3.  A Comparative Analysis of the Corrosive Effect of Artificial Saliva of Variable pH on DMLS and Cast Co-Cr-Mo Dental Alloy.

Authors:  Tatjana Puskar; Danimir Jevremovic; Robert J Williams; Dominic Eggbeer; Djordje Vukelic; Igor Budak
Journal:  Materials (Basel)       Date:  2014-09-11       Impact factor: 3.623

4.  Corrosive Studies of a Prosthetic Ni-Cr Alloy Coated with Ti(C,N) Type Layers.

Authors:  Katarzyna Banaszek; Marek Maślanka; Michael Semenov; Leszek Klimek
Journal:  Materials (Basel)       Date:  2022-03-27       Impact factor: 3.623

5.  Cytokine-Mediated Inflammation in the Oral Cavity and Its Effect on Lipid Nanocarriers.

Authors:  Carolin Tetyczka; Sonja Hartl; Ramona Jeitler; Markus Absenger-Novak; Claudia Meindl; Eleonore Fröhlich; Sabrina Riedl; Dagmar Zweytick; Eva Roblegg
Journal:  Nanomaterials (Basel)       Date:  2021-05-18       Impact factor: 5.076

  5 in total